Use these procedures to verify hardware operation after
making repairs to the system.
Choose from the following options:
- To verify the repair of a system that is currently powered off,
go to step 1.
- To verify the repair of a system that is currently powered on
with no operating system loaded, go to step 3.
- To verify the repair of a system that is currently powered on
and that has an operating system loaded, go to step 5.
- Power on the server and all attached I/O enclosures.
Did all the enclosures power
on? |
Yes: Go
to step 3.↓ Go to step 3. |
No: Continue
with the next step. |
- Choose from the following options:
- If the original problem was that an enclosure would not power
on and you have another FRU to replace, locate and replace the next
field-replaceable unit (FRU).
- If the next FRU in the FRU list is an isolation procedure, perform
the isolation procedure.
- If the original problem was that an enclosure would not power
on and you have an isolation procedure to complete, perform the isolation
procedure.
- If the original problem was that an enclosure would not power
on and there are no more FRUs or isolation procedures in the FRU list,
contact your next level of support.
- If you have a new problem, perform problem analysis and repair
the new problem.
|
- Load the operating system.
Did the operating system load
successfully? |
Yes: Go
to step 5. |
No: Continue
with the next step. |
- Choose from the following options:
- If the original problem was a failing disk drive that contained
the operating system software, go to step 5.
- If the original problem was that the operating system would not
load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
- If the next FRU in the FRU list is an isolation procedure, perform
the isolation procedure.
- If the original problem was that the operating system would not
load and you have an isolation procedure to complete, perform the
isolation procedure.
- If the original problem was that the operating system would not
load and there are no more FRUs or isolation procedures in the FRU
list, contact your next level of support.
- If you have a new problem, perform problem analysis and repair
the new problem.
|
- Choose from the following options: