z/OS Communications Server: SNA Network Implementation Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Application program-to-local SNA over CTCA connection

z/OS Communications Server: SNA Network Implementation Guide
SC27-3672-01

There are two pacing stages for an application program-to-local SNA device session over a CTCA connection. Stage x uses adaptive pacing and stage y can use either adaptive or fixed pacing. Figure 1 shows the pacing stages for this example. See Table 1 and Table 2 for examples of the values used by VTAM® to set the pacing window values.
Figure 1. Application program-to-local SNA device over CTCA connection
Diagram that shows two pacing stages for an application program-to-local SNA device session over a CTCA connection.
Table 1 shows sample definition statement coding and corresponding windows when data flows from the PLU to the SLU.
Table 1. Application program to local SNA device over CTCA connection—PLU to SLU flow

SRCVPAC
MODEENT
macro

PSNDPAC
MODEENT
macro

PACING
operand
(SLU)

VPACING
operand
(SLU)

AUTH
APPL
definition
statement
(PLU)

Send
window
stage x

Send
window
stage y

0

n/a

n/a

4

NVPACE

95

4

0

15

n/a

4

PACE

15

4

5

0

6

n/a

PACE

6

5

Table 2 shows sample definition statement coding and corresponding windows when data flows from the SLU to the PLU.
Table 2. Application program-to-local SNA device over CTCA connection—SLU to PLU flow

SSNDPAC
MODEENT
macro

VPACING
APPL definition
statement (PLU)

Send window
stage x

Send window
stage y

9

2

2

9

0

7 (default)

7

32767

9

0

32767

9

Go to the previous page Go to the next page