Developing healthcare message flow applications by using the patterns supplied in IBM Integration Bus Healthcare Pack

Use the built-in patterns to integrate applications that use HL7 v2 messages.

A built-in pattern is a pattern that covers a set of commonly encountered message flow scenarios and that is packaged and released with IBM® Integration Bus and IBM Integration Bus connectivity packs.

The built-in patterns that are supplied in IBM Integration Bus Healthcare Pack are shown in the following table.

You can view patterns in the documentation by using the links only when you use the documentation that is integrated with the IBM Integration Toolkit, or when you use the online documentation in the IBM Knowledge Center.

Clinical patterns

Pattern name Description
Healthcare: HL7 Transformation The Healthcare: HL7 Transformation pattern generates graphical data maps that you can use to assemble HL7 messages.
Note: This pattern uses the DFDL message model.
Healthcare: HL7 to HL7 DFDL The Healthcare: HL7 to HL7 DFDL pattern integrates an application that can send HL7 (version 2.7, 2.6, 2.5.1 or earlier) messages to one or more applications that can receive HL7 messages. The applications must be able to send and receive the messages by using MLLP over TCP/IP.

You can monitor the Healthcare: HL7 to HL7 DFDL pattern by using operational monitoring, or by using web-based monitoring. See Monitoring clinical applications, or Web-based monitoring.

Note: This pattern uses the DFDL message model.
Healthcare: HL7 to HL7
Note: This pattern was made available in IBM WebSphere® Message Broker Connectivity Pack for Healthcare version 7.0 and is still available and supported in IBM Integration Bus Healthcare Pack version 3.0. However, it is recommended that you use the Healthcare: HL7 to HL7 DFDL pattern instead if possible. The Healthcare: HL7 to HL7 DFDL pattern uses the DFDL message model instead of MRM and the HL7v25P message set. The DFDL message model has the following benefits.
  • DFDL is an open-standard format whereas MRM and the HL7v25P message set are proprietary to IBM Integration Bus.
  • The DFDL editor provides simpler tools for developing and testing extensions to the HL7 schema compared to MRM and the HL7v25P message set.
  • The DFDL message model supports HL7 versions 2.7, 2.6, 2.5.1 and earlier whereas MRM and the HL7v25P message set only support HL7 version 2.5.1 and earlier.
The Healthcare: HL7 to HL7 pattern integrates an application that can send HL7 (version 2.5.1 or earlier) messages to one or more applications that can receive HL7 messages. The applications must be able to send and receive the messages by using MLLP over TCP/IP.

You can monitor the Healthcare: HL7 to HL7 pattern by using operational monitoring, or by using web-based monitoring. See Monitoring clinical applications, or Web-based monitoring.

Note: This pattern uses MRM and the HL7v25P message set.
Healthcare: Medical Devices to EMR The Healthcare: Medical Devices to EMR pattern integrates medical devices with an Electronic Medical Record (EMR) application that can receive HL7 (version 2.5.1 or earlier) observation result messages (ORU R01). The application must be able to receive HL7 ORU R01 messages by using MLLP over TCP/IP.

You can monitor the Healthcare: Medical Devices to EMR pattern by using operational monitoring, or by using web-based monitoring. See Monitoring clinical applications, or Web-based monitoring.

Note: This pattern uses MRM and the HL7v25P message set.
Healthcare: HL7 to Reports The Healthcare: HL7 to Reports pattern integrates an application that can send HL7 (version 2.5.1 or earlier) messages with report generation. The source application must be able to send and receive HL7 messages by using MLLP over TCP/IP.

You can monitor the Healthcare: HL7 to Reports pattern by using operational monitoring, or by using web-based monitoring. See Monitoring clinical applications, or Web-based monitoring.

Note: This pattern uses MRM and the HL7v25P message set.
Healthcare: Web Service to DICOM The Healthcare: Web service to DICOM pattern integrates an application that is written using web services with DICOM applications that support C-FIND and C-MOVE operations. You can use the pattern to query patients, studies, series, and images from a DICOM PACS using a web service that is implemented by IBM Integration Bus

You can monitor the DICOM pattern by using operational monitoring, see Monitoring clinical applications.

Healthcare: Home Health The Healthcare: Home Health pattern enables your health systems to accept web service requests from HL7 v2.6 compliant devices. This allows data that Home Health devices collect and send to the Application Hosting Device (AHD) to then be sent to the requesting clinical application. This pattern uses the DFDL message model.
Start of changeHealthcare: HIPAA to XMLEnd of change Start of changeThe Healthcare: HIPAA to XML pattern creates a messages flow that you can use to convert HIPAA files to XML files.End of change

For more information about using patterns, see Developing message flow applications by using patterns in the IBM Integration Bus product documentation.

Notices | Trademarks | Downloads | Library | Support | Feedback

Copyright IBM Corporation 2011, 2014Copyright IBM Corporation 2011, 2014.

        
        Last updated
        
        Last updated : 2015-12-07 16:17:35


Concept topicConcept topic | Version 3.0.0.1 | ha00160