IXL002I
SYNTAX ERROR IN SYSXES COMPONENT TRACE OPTIONS. keyword IS
AN UNKNOWN KEYWORD.
IXL003I
SYNTAX ERROR IN SYSXES COMPONENT TRACE OPTIONS. option WAS
SEEN WHERE ONE OF: optiona optionb optionc optiond optione optionf optiong optionh optionj optionk WAS
EXPECTED.
IXL014I
requesttype REQUEST FOR STRUCTURE structure-name WAS
SUCCESSFUL. JOBNAME: jobname ASID: asid CONNECTOR
NAME: connector name CFNAME: cfname[statusinfo]
IXL015I
strtype ALLOCATION INFORMATION FORSTRUCTURE
structure-name CONNECTOR NAME connector-nameCONNECTIVITY=connectivityCFNAME ALLOCATION
STATUS/FAILURE REASON------ --------------------------------cfname
text [diag]
IXL020I
CLEANUP FOR LOCK STRUCTURE structure-name,
CONNECTION ID conid, STARTED BY CONNECTOR connector-name INFO: n
IXL021I
GLOBAL CLEANUP FOR LOCK STRUCTURE structure-name,
CONNECTION ID conid, BY CONNECTOR connector-name HAS
COMPLETED. INFO:n
IXL022I
LOCAL CLEANUP FOR LOCK STRUCTURE structure-name,
CONNECTION ID conid, BY CONNECTOR connector-name HAS
COMPLETED. INFO: n
IXL023I
CLEANUP FOR LOCK STRUCTURE structure-name,
CONNECTION ID conid, BY CONNECTOR conname HAS
COMPLETED. INFO: n
IXL024I
text PRIORITY DEFERRED GLOBAL LOCK MANAGER
PROCESSING FOR LOCK STRUCTURE strname, BY CONNECTOR conname HAS
COMPLETED. INFO: n
IXL030I
CONNECTOR STATISTICS FOR LOCK STRUCTURE structure-name,
CONNECTOR connector-name: n
IXL031I
CONNECTOR CLEANUP FOR LOCK STRUCTURE structure-name,
CONNECTOR connector-name, HAS COMPLETED. INFO: n
IXL040E
CONNECTOR NAME: connector-name, JOBNAME: jobname,
ASID: asid HAS text. process FOR
STRUCTURE structure-name CANNOT CONTINUE. MONITORING
FOR RESPONSE STARTED: mondate montime. DIAG: x
IXL041E
CONNECTOR NAME: connector-name, JOBNAME: jobname,
ASID: asid HAS NOT RESPONDED TO THE event FOR
SUBJECT CONNECTION: subject-connector-name. process FOR
STRUCTURE structure-name CANNOT CONTINUE. MONITORING
FOR RESPONSE STARTED: mondate montime. DIAG: x
IXL044I
COUPLING FACILITY cfname HAS EXPERIENCED IfccCount INTERFACE
CONTROL CHECKS ON CHPID chpid DURING THE LAST interval SECONDS.
IXL045E
[REBUILD] CONNECTOR NAME: connector-name,
JOBNAME: jobname, ASID: asid FOR
STRUCTURE structure-name MAY BE ENCOUNTERING DELAYS
DUE TO LIMITED XES SRB SCHEDULING.
IXL046I
[REBUILD] CONNECTOR NAME: connector-name,
JOBNAME: jobname, ASID: asid FOR
STRUCTURE structure-name IS NO LONGER ENCOUNTERING
DELAYS DUE TO LIMITED XES SRB SCHEDULING.
IXL046I
[REBUILD] CONNECTOR NAME: connector-name,
JOBNAME: jobname, ASID: asid FOR
STRUCTURE structure-name IS NO LONGER ENCOUNTERING
DELAYS DUE TO LIMITED XES SRB SCHEDULING.
IXL047I
THE RESPONSE REQUIRED FROM CONNECTOR NAME: conname TO
STRUCTURE strname, JOBNAME: jobname,
ASID: asid responsetype IS
NO LONGER EXPECTED. REASON: reason
IXL048I
THE RESPONSE REQUIRED FROM CONNECTOR NAME: conname TO
STRUCTURE strname, JOBNAME: jobname,
ASID: asid FOR THE event FOR
SUBJECT CONNECTION subjectconnname IS NO LONGER
EXPECTED. REASON: reason
IXL049E
HANG RESOLUTION ACTION FOR CONNECTOR NAME: conname
TO STRUCTURE strname, JOBNAME: jobname,
ASID: asid: actiontext
IXL050I
CONNECTOR NAME: conname TO STRUCTURE strname,
JOBNAME: jobname, ASID: asid
HAS NOT PROVIDED A REQUIRED RESPONSE AFTER noresponsetime SECONDS.
TERMINATING termtarget TO RELIEVE THE HANG.
IXL051E
dumptype DUMP OF COUPLING FACILITY cfnametype.mfg.plant.sequence PARTITION: partition
side CPCID: cpcidINITIATED BY THE requestor [FOR
STRUCTURE strname SID sid] [DIAG
DATA: diagdata]
IXL052E
IXL052I SYSTEM: system-name, CONNECTOR: connector-name, JOBNAME: jobname, ASID: asid, FOR STRUCTURE: structure-name, HAS TIMED OUT REQUEST: request text. actions. MONITORING FOR TIMEOUT STARTED: mm/dd/yyyy hh:mm:ss. TIMEOUT DETECTED: mm/dd/yyyy hh:mm:ss. RESOURCE: resource-id.
IXL103I
VARY REJECTED, COUPLING FACILITY cfname IS
NOT ACCESSIBLE
IXL104I
VARY REJECTED, PATH(cfname,chpid)
DOES NOT EXIST
IXL105I
VARY REJECTED, PATH(cfname,chpid)
LAST PATH TO FACILITY
IXL106I
VARY REJECTED, PATH(cfname,chpid)
LAST PATH TO ACTIVE FACILITY
IXL124I
CONFIG REJECTED, CHP(chpid) LAST PATH
TO COUPLING FACILITY cfname
IXL125I
CONFIG REJECTED, CHP(chpid) LAST PATH
TO ACTIVE COUPLING FACILITY cfname
IXL126I
CONFIG WILL FORCE OFFLINE LAST CHP(chpid)
TO COUPLING FACILITY cfname