IXL162E
CF REQUEST TIME ORDERING: REQUIRED AND WILL NOT BE ENABLED text reason

Explanation

CF request time ordering is required for operations to this coupling facility; however the timing characteristics of the coupling facility are not consistent with timing characteristics of the z/OS® system. The coupling facility is identified by the node descriptor. See mapping macro IXLYNDE. The reason why that CF request time ordering will not be enabled is described in the message text.

text
text is
COUPLING FACILITY   type.mfg.plant.sequence
                    PARTITION: partition side  CPCID: cpcid            
type
Node type (See ndetype in IXLYNDE).
mfg
Node manufacturer ID (See ndemfg in IXLYNDE).
plant
Node manufacturer plant ID (See ndeplant in IXLYNDE).
sequence
Node sequence number (See ndesequence in IXLYNDE).
partition
Node LPAR partition number (See ndepartition in IXLYNDE).
side
The node PP/SI mode indicator and configuration code from the IXLYNDE are used to determine the value for side. Value and meaning are:
  • SIDE: 0 means that the coupling facility is on SIDE 0 of a partitionable CPC.
  • SIDE: 1 means that the coupling facility is on SIDE 1 of a partitionable CPC.
  • Blank means that the coupling facility is in a non-partitionable CPC.
cpcid
Node Central Processor Complex (CPC) ID (See ndecpcid in IXLYNDE).
reason
reason is one of the following:
REASON: CTNID MISMATCH - CF CTNID: cfstpid-cfetrid
The CF request time ordering function is required for operations to the CF; however, the CTNID that is defined for the CEC that is running the CF does not match the CTNID that is defined for the CEC that is running the z/OS system. The cfstpid is the eight-byte STP portion of the CTNID that has been defined for the CEC running the CF. The cfetrid is the ETR Network ID of the ETR that is connected to the Coupling Facility.

Issue D ETR to obtain CTN information for the CEC running the z/OS system.

In the message text:

System action

The system will discontinue using the coupling facility if the timing characteristics are not corrected within 24 seconds.

Operator response

Notify the system programmer if the coupling facility identified is critical for system operations.

System programmer response

Based on the reason described in the message, determine the cause of the failure and correct it.

Source

Cross System Extended Services (XES)

Module

IXLC3VSC

Routing code

1,2,10

Descriptor code

11