IXL049E
HANG RESOLUTION ACTION FOR CONNECTOR NAME: conname TO STRUCTURE strname, JOBNAME: jobname, ASID: asid: actiontext

Explanation

An XES process is in a possible hang condition because the connector did not provide a required response to one or more events, described by message IXL040E or IXL041E. This message indicates whether and when the system will take automatic action to relieve the hang.

In the message text:
conname
Name of the connector with one or more overdue responses.
strname
The name of the structure with which the affected connector is associated.
jobname
Job name of the connector.
asid
Hexadecimal ASID of the connector.
actiontext
One of the following:
SFM POLICY NOT ACTIVE, MANUAL INTERVENTION REQUIRED
There is no SFM policy active on the local system, so the system will not take action to remedy the problem. The installation should immediately investigate and resolve the problem.
SFM POLICY REQUIRES MANUAL INTERVENTION
CFSTRHANGTIME(NO) is in effect for the local system (either defaulted or explicitly specified in the SFM policy), so the system will not take action to remedy the problem. The installation should immediately investigate and resolve the problem.
SYSTEM IS TAKING ACTION
The system is taking immediate action to remedy the problem, either because the SFM policy specified CFSTRHANGTIME(0) for the local system or because an SFM policy change activated a new value of CFSTRHANGTIME which, when applied to the hang detection time, caused action to be required at the present time.
SYSTEM WILL TAKE ACTION AT termdate termtime
If the outstanding response has not been provided by the date and time indicated, the system will take action to remedy the problem.
SYSTEM ACTION UNSUCCESSFUL, MANUAL INTERVENTION REQUIRED
The system has attempted all forms of automatic action of which it is capable. The connector response remains outstanding, and the affected process remains hung. The installation should investigate and resolve the problem.
termdate
The date when the system will take action to resolve the hang caused by the unresponsive connector (mm/dd/yyyy). The date is in months (01-12), days (01-31), and year.
termtime
The time when the system will take action to resolve the hang caused by the unresponsive connector (hh:mm:ss). The time is in hours (00-23), minutes (00-59), and seconds (00-59).

System action

If SFM is in use on the local system and an SFM policy is active, the system uses the CFSTRHANGTIME specification from the currently active policy to determine whether and when to initiate automatic action to resolve the hang.

If the system is not using SFM, the default behavior is to take no automatic action, as if CFSTRHANGTIME(NO) is specified.

If the message indicates that manual intervention is required, the system continues to monitor the situation.

If the message indicates that the system is taking action, the system will initiate progressively more aggressive actions as necessary to resolve the hang. System actions may include stopping a rebuild, terminating the connector's task or address space, or partitioning the issuing system. If connector termination is necessary, the system will initiate a dump. The system will issue message IXL050I to indicate that action is being taken against the hung connector to resolve the problem.

If the message indicates that the system will take action at a specific time, the CFSTRHANGTIME specification of the SFM policy has been applied to calculate the maximum amount of time that the connector will be permitted to remain unresponsive. If the outstanding response has not been provided by the specified time, the system will then initiate action to resolve the hang. If automatic action becomes necessary, the system will issue message IXL050I and may initiate a dump.

Operator response

Notify the system programmer.

System programmer response

Refer to the documentation for messages IXL040E and IXL041E.

Source

Cross System Extended Services (XES)

Module

IXLM1TMR

Routing code

2,10

Descriptor code

7, 11