Explanation
VTAM® issues
this message as a single message or as part of several message groups.
If this message is preceded by message IST734I (cross-network session),
see the explanation of that message for additional information.
Possible
message groups follow.
- ACTCDRM
This host received an
ACTCDRM request from
an external CDRM.
- If IST732I is issued as a single message, the request cannot be
processed for the following reason:
- HOST CDRM INACTIVE
- No CDRM major node containing a definition for the host CDRM was
active or the host CDRM is inactive.
- Otherwise, IST732I is issued as the first message in the following
group:
IST732I request REJECTED DUE TO reason
IST725I GWN gatewayncp, SUBAREA subarea, CDRM ALIAS ELEMENT element
IST726I ADJNET adjnetid, ADJNETSA adjnetsubarea, ADJNETEL adjnetel
The request cannot be processed for the following
reason:
- SENDING CDRM UNKNOWN
- The sender of the ACTCDRM request is not defined in this host.
gatewayncp is the name
of a gateway NCP.
subarea and element are
the subarea and element portions of the alias address of the external
CDRM in this network.
The address of the CDRM, as defined in
the adjacent network adjnetid, is subarea adjnetsubarea and
element adjnetel.
- REQACTCDRM
This host received a
REQACTCDRM request from
external CDRM
cdrmname over a gateway NCP path.
IST732I request REJECTED DUE TO reason
[IST1421I nodetype resourcename HAS DUPLICATE ADDRESS]
IST721I SESSION SETUP FOR CDRM cdrmname USING GWN gatewayncp FAILED
IST726I ADJNET adjnetid, ADJNETSA adjnetsubarea, ADJNETEL adjnetel
[IST830I ORIGINATING SSCP NAME = sscpname, NETID = netid]
The request cannot be processed for one of the
following
reasons:
- ACTIVATE IN PROGRESS
- Either the origin CDRM or the destination CDRM is pending active.
- ADDRESS NOT A CDRM
- The adjacent network address in message IST726I is in use by a
resource that is not a CDRM. For the REQACTCDRM to succeed, the adjacent
network address MUST be a CDRM resource. resourcename in
message IST1421I contains the name of the resource using the address
(if the name is available).
- HOST CDRM INACTIVE
- No CDRM major node containing a definition for the host CDRM was
active or the host CDRM is inactive.
- INACT IN PROGRESS
- The origin CDRM, the destination CDRM, or the CDRM major node
is pending inactive.
- INSUFFICIENT STORAGE
- No storage could be allocated to proceed with session setup.
- SENDING CDRM UNKNOWN
- The sender of the ACTCDRM is not defined in this host.
- SENDING GWN INACTIVE
- There is no active definition for the gateway NCP gatewayncp that
sent the REQACTCDRM.
- SENDING GWN INVALID
- No GWPATH definition exists for the gateway NCP gatewayncp that
sent the REQACTCDRM.
gatewayncp is the name
of the gateway NCP.
The address of CDRM cdrmname,
as defined in the adjacent network adjnetid, is
subarea adjnetsubarea and element adjnetel.
The REQACTCDRM originated
with SSCP sscpname in network netid.
If sscpname or netid are not
known to VTAM, they will be
displayed as ***NA***.
System action
The session could not be established.
Operator response
Do one of the following, depending upon
reason:
- ACTIVATE IN PROGRESS
- No action is required.
- ADDRESS NOT A CDRM
- Enter a DISPLAY ID=resourcename using cdrmname from
message IST1421I. Enter a DISPLAY VTAMSTOR,NETID=adjnetid,NETADDR=(adjnetsubarea,adjnetel)
command using the values from message IST726I. Save the console log
for problem determination.
- HOST CDRM INACTIVE
- Activate a CDRM major node containing the host CDRM definition,
if the major node is active, or activate the host CDRM.
- INACT IN PROGRESS
- Allow the deactivation to complete and then try the activation
again.
- INSUFFICIENT STORAGE
- Enter a DISPLAY BFRUSE or DISPLAY STORUSE command to evaluate
your storage requirements. Save the system log and dump for problem
determination.
- SENDING CDRM UNKNOWN
- If the CDRM major node contains the definition of the external
CDRM then activate it. Otherwise, save the system log and network
logs and print the CDRM definition statement for problem determination.
- SENDING GWN INACTIVE
- Activate the gateway NCP.
- SENDING GWN INVALID
- Save the system log and network logs and print the CDRM definition
statement for problem determination.
System programmer response
- ADDRESS NOT A CDRM
- Check your network address assignments to determine which resource
should be using the adjacent network address.
- INSUFFICIENT STORAGE
- Verify that the operator entered the buffer pool or CSA start
options as specified in the start procedures. Increase storage as
required. For insufficient storage errors, you might want to redefine
your buffer pool or CSA start options. If the start option cannot
be modified using the MODIFY VTAMOPTS command, you must modify the VTAM start options file (ATCSTRxx)
and restart VTAM to use the
start option.
- SENDING GWN INVALID
- You need to add a gateway path definition for the gateway NCP
that sent the REQACTCDRM. To use the new definition, you must deactivate
and reactivate the CDRM major node that contains the new GWPATH definition.
- SENDING CDRM UNKNOWN
- You need to add a CDRM definition statement for cdrmname.
To use the new definition, you must deactivate and reactivate the
CDRM major node.
Routing code