IST732I
request REJECTED DUE TO reason

Explanation

VTAM® issues this message as a single message or as part of several message groups. If this message is preceded by message IST734I (cross-network session), see the explanation of that message for additional information.

Possible message groups follow.
  • ACTCDRM
    This host received an ACTCDRM request from an external CDRM.
    • If IST732I is issued as a single message, the request cannot be processed for the following reason:
      HOST CDRM INACTIVE
      No CDRM major node containing a definition for the host CDRM was active or the host CDRM is inactive.
    • Otherwise, IST732I is issued as the first message in the following group:
       IST732I  request REJECTED DUE TO reason
       IST725I  GWN gatewayncp, SUBAREA subarea, CDRM ALIAS ELEMENT element
       IST726I  ADJNET adjnetid, ADJNETSA adjnetsubarea, ADJNETEL adjnetel
       
      The request cannot be processed for the following reason:
      SENDING CDRM UNKNOWN
      The sender of the ACTCDRM request is not defined in this host.

      gatewayncp is the name of a gateway NCP.

      subarea and element are the subarea and element portions of the alias address of the external CDRM in this network.

      The address of the CDRM, as defined in the adjacent network adjnetid, is subarea adjnetsubarea and element adjnetel.

  • REQACTCDRM
    This host received a REQACTCDRM request from external CDRM cdrmname over a gateway NCP path.
     IST732I  request REJECTED DUE TO reason
     [IST1421I nodetype resourcename HAS DUPLICATE ADDRESS]
    IST721I  SESSION SETUP FOR CDRM cdrmname USING GWN gatewayncp FAILED
     IST726I  ADJNET adjnetid, ADJNETSA adjnetsubarea, ADJNETEL adjnetel
    [IST830I  ORIGINATING SSCP NAME = sscpname, NETID = netid]
     
    The request cannot be processed for one of the following reasons:
    ACTIVATE IN PROGRESS
    Either the origin CDRM or the destination CDRM is pending active.
    ADDRESS NOT A CDRM
    The adjacent network address in message IST726I is in use by a resource that is not a CDRM. For the REQACTCDRM to succeed, the adjacent network address MUST be a CDRM resource. resourcename in message IST1421I contains the name of the resource using the address (if the name is available).
    HOST CDRM INACTIVE
    No CDRM major node containing a definition for the host CDRM was active or the host CDRM is inactive.
    INACT IN PROGRESS
    The origin CDRM, the destination CDRM, or the CDRM major node is pending inactive.
    INSUFFICIENT STORAGE
    No storage could be allocated to proceed with session setup.
    SENDING CDRM UNKNOWN
    The sender of the ACTCDRM is not defined in this host.
    SENDING GWN INACTIVE
    There is no active definition for the gateway NCP gatewayncp that sent the REQACTCDRM.
    SENDING GWN INVALID
    No GWPATH definition exists for the gateway NCP gatewayncp that sent the REQACTCDRM.

    gatewayncp is the name of the gateway NCP.

    The address of CDRM cdrmname, as defined in the adjacent network adjnetid, is subarea adjnetsubarea and element adjnetel.

    The REQACTCDRM originated with SSCP sscpname in network netid. If sscpname or netid are not known to VTAM, they will be displayed as ***NA***.

System action

The session could not be established.

Operator response

Do one of the following, depending upon reason:
ACTIVATE IN PROGRESS
No action is required.
ADDRESS NOT A CDRM
Enter a DISPLAY ID=resourcename using cdrmname from message IST1421I. Enter a DISPLAY VTAMSTOR,NETID=adjnetid,NETADDR=(adjnetsubarea,adjnetel) command using the values from message IST726I. Save the console log for problem determination.
HOST CDRM INACTIVE
Activate a CDRM major node containing the host CDRM definition, if the major node is active, or activate the host CDRM.
INACT IN PROGRESS
Allow the deactivation to complete and then try the activation again.
INSUFFICIENT STORAGE
Enter a DISPLAY BFRUSE or DISPLAY STORUSE command to evaluate your storage requirements. Save the system log and dump for problem determination.
SENDING CDRM UNKNOWN
If the CDRM major node contains the definition of the external CDRM then activate it. Otherwise, save the system log and network logs and print the CDRM definition statement for problem determination.
SENDING GWN INACTIVE
Activate the gateway NCP.
SENDING GWN INVALID
Save the system log and network logs and print the CDRM definition statement for problem determination.

System programmer response

ADDRESS NOT A CDRM
Check your network address assignments to determine which resource should be using the adjacent network address.
INSUFFICIENT STORAGE
Verify that the operator entered the buffer pool or CSA start options as specified in the start procedures. Increase storage as required. For insufficient storage errors, you might want to redefine your buffer pool or CSA start options. If the start option cannot be modified using the MODIFY VTAMOPTS command, you must modify the VTAM start options file (ATCSTRxx) and restart VTAM to use the start option.
SENDING GWN INVALID
You need to add a gateway path definition for the gateway NCP that sent the REQACTCDRM. To use the new definition, you must deactivate and reactivate the CDRM major node that contains the new GWPATH definition.
SENDING CDRM UNKNOWN
You need to add a CDRM definition statement for cdrmname. To use the new definition, you must deactivate and reactivate the CDRM major node.

Routing code

8

Descriptor code

4