z/OS Communications Server: SNA Network Implementation Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Verifying a multiple-domain subarea network

z/OS Communications Server: SNA Network Implementation Guide
SC27-3672-01

Verify that your multi-domain subarea network functions properly after you verify a VTAM® network.

Before you begin

Perform the steps Verifying a VTAM network for each domain in your network. After you have done this, make a list of the most important normal and backup operations in your network, and verify each of them one at a time. Then verify the network over a length of time, as in normal operation.

Procedure

To verify that your multiple-domain, subarea network functions properly, do the following steps:

  1. Activate cross-domain paths and links, cross-domain resource managers (CDRMs), and cross-domain resources (CDRSCs).
  2. Verify cross-domain sessions by exchanging requests across domains, between terminals and hosts, and between application programs.
  3. Verify the NetView® program, if it is installed.
  4. Verify host backup using a channel-attached, shared NCP.
  5. Verify host backup over a cross-domain link.
  6. Verify automatic SSCP-SSCP session restart.
  7. Halt VTAM in each domain.

Go to the previous page Go to the next page