The following sample illustrates how to code for SDLC
primary and secondary links and link stations.
PRIM SDLCST GROUP=GPRIM, PRIMARY GROUP NAME
MAXOUT=127, LINK LEVEL RESPONSE
MODE=PRIMARY, PRIMARY MODE
PASSLIM=254, MAXIMUM PIU SEND COUNT
RETRIES=(7,3,5), RETRY COUNTS
⋮
SERVLIM=254 SERVICE ORDER TABLE SCAN
*
SEC SDLCST GROUP=GSEC, SECONDARY GROUP NAME
MAXOUT=127, LINK LEVEL RESPONSE
MODE=SECONDARY, SECONDARY MODE
PASSLIM=254, MAXIMUM SEND COUNT
RETRIES=(7), RETRY COUNT
⋮
TADDR=C1 SECONDARY POLL ADDRESS
*
*
GPRIM GROUP LNCTL=SDLC, SDLC LINK CONTROL
TYPE=NCP, NCP LINK
DIAL=NO, NONSWITCHED CONNECTION
REPLYTO=(1.0,3.0), REPLY TIMEOUT
MODE=PRIMARY, PRIMARY link station
⋮
MODULO=128 MODULO FOR LINK LEVEL RESPONSE
*
GSEC GROUP LNCTL=SDLC, SDLC LINK CONTROL
TYPE=NCP, NCP LINK
DIAL=NO, NONSWITCHED CONNECTION
REPLYTO=(NONE,NONE), NO REPLY TIMEOUT ON SECONDARY
MODE=SECONDARY, SECONDARY link station
MODULO=128, MODULO FOR LINK LEVEL RESPONSE
⋮
ACTIVTO=120 ACTIVATE TIMEOUT