z/OS MVS Setting Up a Sysplex
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Determining the connection states

z/OS MVS Setting Up a Sysplex
SA23-1399-00

To determine the state of all connections for a given structure, issue the following command: DISPLAY XCF,STRUCTURE,STRNAME=strname

Message IXC360I will provide information about the stucture and its connectors. Figure 1 is an example of displaying information about an IRLM lock structure: DISPLAY XCF,STRUCTURE,STRNAME=IRLMLOCK1
Figure 1. Example: Displaying information about an IRLM lock structure
IXC360I    12.23.28  DISPLAY XCF xxx
STRNAME:  IRLMLOCK1
 STATUS:   ALLOCATED
                '
                '

                /  (only relevant portions or message IXC360I
                /    are shown here)                
                '
                '
CONNECTION NAME    ID   VERSION   SYSNAME   JOBNAME    ASID  STATE
-----------------  --   --------  --------  --------   ----  ------
IRLMGRP1$IRLA001   03   0003002F  SYS1       IRLMA     001D  ACTIVE
IRLMGRP1$IRLB002   02   0002008C  SYS2       IRLMB     0058  ACTIVE
IRLMGRP1$IRLC003   01   00010099  SYS3       IRLMC     003F  FAILING 
IRLMGRP1#IRLC004   04   0004001A  SYS3       IRLMC     0180  DISCONNECTING

In Figure 1, connections 03 and 02 are ACTIVE (normal), and connections 01 and 04 are in transition.

Go to the previous page Go to the next page