z/OS DFSMS Managing Catalogs
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


The intersection of SYSCATxx, LOADxx, IGGCATxx, and MODIFY CATALOG command

z/OS DFSMS Managing Catalogs
SC23-6853-00

There are several places to define catalog configuration values: SYSCATxx, LOADxx, IGGCATxx, and the MODIFY CATALOG command. Table Table 1 shows which attributes you can specify in each. However, for complete information, see the following:

The system applies the parameters in IGGCATxx, LOADxx, and SYSCATxx in the following order:

  1. Parmlib member IGGCATxx, if specified, takes the highest priority, followed by...
  2. Parmlib member LOADxx followed by...
  3. SYSCATxx member of SYS1.NUCLEUS followed by...
  4. System defined defaults
IGGCATxx overlaps extensively with the MODIFY CATALOG command, as you can see in Table 1. The system applies IGGCATxx values at IPL time as well as at the restart of the Catalog Address Space, while command configuration changes are temporary, lasting only until the next IPL.
Note:

Some of these attributes are specified by subparameters of the CONTENTION, ECSHR, ENABLE, or DISABLE parameters of the MODIFY CATALOG command.

Table 1. Intersection of SYSCATxx, LOADxx, IGGCATxx, and MODIFY CATALOG command
Keyword Attribute IGGCATxx LOADxx SYSCATxx MODIFY CATALOG
  Master catalog name No Yes Yes No
  Master catalog type No Yes Yes No
  Master catalog volume No Yes Yes No
ALIASLEVEL Number of data set name qualifiers to be used in the multilevel alias facility catalog search Yes Yes Yes Yes
ALLOCLCK Contention detection settings for ALLOCLCK resource Yes No No CONTENTION
AUTOADD AUTOADD function Yes Yes Yes ECSHR
CATMAX Maximum number of catalogs that can be opened concurrently in CAS Yes No No Yes
DELFORCEWNG Warning message IDC1997I or IDC1998I Yes No No ENABLE | DISABLE
DELRECOVWNG Warning message IDC1999I Yes No No ENABLE | DISABLE
DSNCHECK Syntax checking on names being added to a catalog Yes No No ENABLE | DISABLE

DUMPOFF
DUMPON

CAS dynamic dumping Yes No No Yes
EXTENDEDALIAS Ability to create extension records for user catalog aliases on the current system Yes No No ENABLE | DISABLE
GDGFIFOENABLE FIFO ordering of GDG Yes No No No
NOTIFYEXTENT Monitor percentage of the maximum extents possible for a currently allocated catalog Yes No No Yes
SYMREC Creation of SYMREC records Yes No No ENABLE | DISABLE

SYS%OFF
SYS%ON

SYS% conversion Yes No Yes Yes
SYSIGGV2 Contention detection settings for SYSIGGV2 resource Yes No No CONTENTION
SYSZTIOT Contention detection settings for SYSZTIOT resource Yes No No CONTENTION
SYSZVVDS Contention detection settings for SYSZVVDS resource Yes No No CONTENTION
TAPEHLQ Tape volume catalog high level qualifier Yes Yes Yes No
TASKMAX Maximum number of concurrent user service tasks Yes No No Yes
TASKMIN CAS service task lower limit (minimum number of CAS service tasks or requests) Yes Yes No Yes
TASKTABLESIZE Start of change CAS task table size End of change Yes No Yes No
UPDTFAIL Warning message IEC390I Yes No No ENABLE | DISABLE
VVDSSPACE Catalog volume data set space allocation Yes No No Yes
VVRCHECK Enhanced VVR checking on VVDS I/O Yes No No ENABLE | DISABLE

Start of change If you wish to suppress the IEA347A message that prompts for the master catalog name at IPL time, you must use the LOADxx member. Note that this means that the system uses the default TASKTABLESIZE value. If you want a larger TASKTABLESIZE , you must specify it in the SYSCATxx parmlib member and you cannot supress the IPL prompt. End of change

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014