Table 1. DEVICE Statement Defaults
and Associated ParametersParameter |
Default (By Device Type) |
---|
Printer |
Punch |
---|
FORMS
|
YES,STANDARD
|
YES,STANDARD
|
CARRIAGE
|
YES,STANDARD
|
N/A
|
TRAIN
|
NO,STANDARD
|
N/A
|
XLATE
|
YES
|
N/A
|
BURST
|
YES
|
YES
|
HEADER
|
YES
|
YES
|
LINELIM
|
0+
|
0+
|
PAGELIM
|
0
|
0
|
PRMODE
|
LINE
|
LINE
|
DYNAMIC
|
YES
|
YES
|
Parameter
|
Usage
|
---|
DTYPE=(RMT1403) or (RMT3211)
|
Required (Note 1)
|
JNAME
|
Required (Note 2)
|
FORMS
|
Optional (Note 3)
|
CARRIAGE
|
Optional
|
TRAIN
|
Optional
|
XLATE
|
Optional
|
BURST
|
Optional
|
HEADER
|
Optional
|
DYNAMIC
|
Optional
|
LINELIM
|
Optional
|
PAGELIM
|
Optional
|
PRMODE
|
Optional
|
JUNIT
|
Optional (Notes 3 and 4)
|
DGROUP
|
Ignore (Note 5)
|
XTYPE
|
Ignore
|
XUNIT
|
Ignore
|
Note: - The DTYPE must be specified, and the first characters must be
RMT. If remote printer FCB loading is desired, specify 3211 as the
last 4 characters; any characters other than 3211 in the last positions
will be ignored.
- The JNAME consists of an 8-character name, where characters 1
through 5 are the terminal name, characters 6 and 7 are PR or PU (for
the device type), and the 8th character is a single digit (1 through
7). This digit must correspond to the device number specified during
remote generation for the device being referenced.
- “Optional” indicates that the parameter may or may not be coded.
- The JUNIT parameter is meaningful for RJP printers and punches
only for setting the device initially online or offline. If this
parameter is omitted, the default setting is "initially online". When JUNIT is specified, you should specify a device
number of NONE or code a "null" value as a place holder. The destination
class is ignored.
- “Ignore” indicates that the parameter has no meaning for remote
devices, and will be ignored.
|
Table 2. CONSOLE Statement
Parameters Associated with RJPTERMParameter
|
Default
|
Usage
|
---|
TYPE=RJP
|
|
Required (Note 1)
|
JNAME=terminal name
|
|
Required
|
DEST (Note 2)
|
|
Required
|
LEVEL
|
00
|
Optional (Note 3)
|
LL
|
120/PRW=
|
Optional
|
MAIN
|
|
Rejected
|
UNIT
|
|
Rejected
|
Note: - “Required” indicates that this parameter must be specified.
- Destinations MLG, OUTPUT, or TOTAL should not be routed to a remote
console.
- “Optional” indicates that this parameter may be coded if the default
is not acceptable.
|
- N=
- Required to indicate the name for this work station. This name
must be 5 characters and cannot be the same as an N parameter specified
on an RJPLINE or RJPWS statement.
Note: IBM® recommends
that a TSO userid should not have the same name as an RJP workstation,
group name, or device. This avoids ambiguity when routing inbound
SYSOUT data sets.
- T=
- Indicates a 4-character identifier specifying the type of work
station. The valid types for this parameter are:
- ID
- Work Station
- 1130
- 1130 processor terminal
- 2770
- 2770 nonprogrammable terminal
- 2780
- 2780 nonprogrammable terminal
- 2922
- 2922 programmable terminal
- 3741
- 3741 nonprogrammable terminal. (See 3741 Restrictions and Limitations for additional information.)
- 3747
- 3747 nonprogrammable terminal
- 3780
- 3780 nonprogrammable terminal
- M202
- System/360, Model 20, Submodel 2, processor
terminal
- M205
- System/360, Model 20, Submodel 5, processor
terminal
- S360
- All System/360 Model 22 and above processor
terminals
- S370
- All System/370 programmable terminals
- SYS3
- System 3, Model 10, processor terminal
In specifying termtype, the following terminals
are specified as 2770s: 3771, 3772, 3773, 3774, and 3775. The 3776
and 3777-1 are specified as 3780s. The 3777-2 is specified as M205.
The value of the T parameter determines the default value for
the C and B parameters.
- B=
- Indicates the terminal buffer size in bytes. The value specified
can be up to 4 numeric characters. For programmable terminals, the
bufsize must correspond to the work station package. For nonprogrammable
terminals, the default buffer value is used.
The default value
for B is determined by the T parameter as shown below: - T Parameter
- B Default
- 1130
- 400
- 2770
- 512
- 2780
- 400
- 2922
- 400
- 3741
- 512
- 3747
- 512
- 3780
- 512
- M202
- 400
- M205
- 400
- S360
- 400
- S370
- 400
- SYS3
- 400
For fixed buffer size devices, such as the 2780,
the B parameter is forced to 400. If F=XBUF is specified, then B defaults
to 256.
- C=
- Indicates the type of console support for this work station. If
the C parameter is specified, a CONSOLE statement should be specified
also. If you omit a CONSOLE statement for this work station, a default
JES3 message destination class of TP (teleprocessing) is assigned
to the console. If a CONSOLE statement is found and the C parameter
is not specified, then the default value for C is assumed.
- R
- Applies to programmable terminals only. This subparameter indicates
the presence of a real console.
- S
- Applies to both programmable and nonprogrammable terminals. This
subparameter specifies that regardless of any real console attached
to this work station, the printer designated as PR1 is to be used
as a simulated console output device.
If S is specified for a programmable
terminal that has a real console, that console can still be used to
enter console commands. However, all console output will be directed
to the printer.
Parameter Default: The default value for C is
determined by the T parameter as follows: - T Parameter
- C Default
- 1130
- R
- 2770
- S
- 2780
- S
- 2922
- R
- 3741
- S
- 3747
- S
- 3780
- S
- M202
- R
- M205
- R
- S360
- R
- S370
- R
- SYS3
- R
- F=HTAB
- Specifies that this terminal has the printer horizontal format
control feature. This parameter is used to indicate a 2770, 2780,
or 3780 with the horizontal format control feature.
If you omit
this parameter, JES3 assumes that the terminal does not have this
feature.
- F=NTRS
- Specifies that the terminal transparency feature is not present
on this terminal.
If you omit this parameter, JES3 assumes that
the terminal has the transparency feature.
- F=PRES
- Specified for a nonprogrammable terminal only, to indicate the
blank compression/expansion feature for that terminal.
If you omit
this parameter, JES3 assumes that the terminal does not have this
feature.
- F=XBUF
- Specifies that a 2770 terminal has the extended buffer feature,
that a 2780 terminal has the multirecord feature, or that a 3740 has
the expanded communications feature. For a 2770, the B parameter must
be specified large enough to incorporate this feature.
If you omit
this parameter, JES3 assumes that the terminal does not have this
feature.
- G=
- Used for the groupname facility. This parameter associates this
work station with a groupname. The groupname specified may be up to
8 characters.
If you omit this parameter, JES3 uses the terminal
name specified in the N parameter.
- O=AUTR
- Indicates a work station option that provides the JES3 automatic
call reader function in the local system. If the T parameter identifies
a nonprogrammable terminal, this option is assumed; the O=AUTR parameter
does not have to be specified.
- O=BFIX
- Indicates a work station option which specifies that the output
buffers used by RJP must be dedicated, that is, obtained at OPEN time
and freed at CLOSE.
- O={DC2|DC3}
- Indicates the punch select character to be used for remote 2770
or 3780 terminals. DC2 specifies device component position 2 on the
terminal. When the 3777-1 is used as a 3780, the O parameter must
indicate DC2. DC3 specifies device component position 3 on the terminal.
If you specify an invalid subparameter, JES3 uses the parameter default.
- O=CCNT
- Specifies, for 3740 terminals, the carriage control characters
that should be sent to the remote printer. If the parameter is specified,
the remote operator should load program buffer A before initiating
printing.
- PR=
- Indicates the number of remote printers associated with this work
station. This parameter specifies a single digit with a maximum value
of 7. Nonprogrammable terminals can have a maximum of one printer.
- PRW=
- For programmable terminals, the value specified on the PRW parameter
must not exceed the buffer size minus 16. The B parameter defines
the buffer size. For nonprogrammable terminals, the value specified
on the PRW parameter must not exceed the maximum print record size
defined by the design of the specific printer. The component document
for the printer defines the maximum print record size.
The NOTRUNC
subparameter is only allowed when the PRW keyword is used for an 3700
device type. NOTRUNC specifies if trailing blanks should be sent to
a D/T3780. If NOTRUNC is coded, then trailing blanks will be sent.
Otherwise, trailing blanks will be suppressed.
- PU=
- Indicates the number of remote punches associated with this work
station. This parameter specifies a single digit with a maximum value
of 7. Nonprogrammable terminals can have a maximum of one punch.
JES3 will pad a blank card at the end of all punch files regardless
of their punch type.
Note: JES3 pads
with a blank card at the end of all punch files regardless of their
punch type.
- PUW=
- Indicates the maximum punch card record size for remote punch
devices. For programmable terminals, the value specified for recsiz
must not exceed the buffer size minus 16. The B parameter defines
the buffer size. If recsiz is larger than bufsiz, JES3 assumes the
default, 80.
For nonprogrammable terminals, the value specified
for recsiz must not exceed the maximum punch card record size defined
by the design of the specific device. The component document for the
device defines the maximum record size.
- RD=
- Indicates the maximum number of readers at this work station.
This parameter specifies a single digit with a maximum value of 7.
Nonprogrammable terminals can have a maximum of one reader.
- P=
- Specifies the 1- to 8-character password of the terminal. This
password must be used by any work station trying to sign on. You can
also use RACF® to provide BSC RJP sign on protection.
The P parameter is ignored when RACF sign
on protection is enabled. See z/OS JES3 Initialization and Tuning Guide for additional information about using RACF to provide security for BSC RJP work stations.
- CS=
- Specifies the type of compression, if any, that is desired. This
parameter is for programmable terminals only.
- Y
- Indicates that equal-character compression is requested for this
terminal.
- B
- Indicates that blank compression only is requested for this terminal.
- N
- Indicates that no compression is requested.
- SET=
- Specifies the type of setup that is desired on remote printers.
- Y
- Indicates that setup is required on remote printers each time
a work station signs on.
- N
- Indicates that setup is not required on remote printers when a
work station signs on.
- V
- Specifies that the work station printer automatically will go
through setup procedures when varied online.
- B
- Specifies that the work station printer automatically will go
through setup procedures when varied online, or the first time accessed
after a LOGON.
|