z/OS JES2 Messages
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


 

z/OS JES2 Messages
SA32-0989-01

 
CES RECEIVED DURING SIGNON IS LESS THAN PREVIOUS SIGNON, RC=19

Explanation

JES2 received a network connection control (NCC) record on line lna which has a connection event sequence (CES) value that is less than a CES value previously associated with this connection.

System action

JES2 fails the signon attempt.

Operator response

Verify that the time-of-day clock on each node is set correctly. Attempt to restart the NJE session at some later time.

System programmer response

This problem can be caused if a node was IPLed with a time-of-day clock value that is less than that used when the system was brought down. If this is the case, NJE cannot be restarted until the time-of-day clock has reached the CES last associated with the connection. Use the $D CONNECT command to display the CES associated with a connection.

Module

HASPNPM

Routing Code: 1,2,8,10

Descriptor Code: 4

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014