z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZD1971I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1971I
SYSPLEX DISTRIBUTOR CONTROL CONNECTION TO DESTINATION IP ADDRESS ip_addr FAILED WITH RETURN CODE errno REASON CODE errnojr

Explanation

The control connection to the non-z/OS target could not be established. The non-z/OS target cannot be used for distributed connections. The control connection can fail if no route is available to the target, or if there is a problem with the sysplex distributor agent server on the target.

In the message text:
ip_addr
The IP address of a distributed non-z/OS target.
errno
A UNIX System Services return code from a failing Connect( ) call. These return codes are listed and described in the return codes (errnos) information in z/OS UNIX System Services Messages and Codes.
errnojr
The hexadecimal UNIX System Services reason code from a failing Connect( ) call. The format of the 4-byte reason code is explained in the introduction to the reason codes (errnojrs) information in the z/OS UNIX System Services Messages and Codes, where the reason codes are listed.

System action

TCP/IP continues.

Operator response

Contact the system programmer.

System programmer response

Fix the problem after analyzing the return code and the reason code. For example, if the return code is 00000468 (ECONNREFUSED), verify that the sysplex distributor agent server is in LISTEN state and that it is accepting new connections. After you fix the problem, the sysplex distributor will establish the control connection because the sysplex distributor periodically tries the connection attempt again.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Sysplex Distributor

Module

EZBXFSUB

Routing code

2,8

Descriptor code

12

Automation

This message is written to the system console. This message is a good candidate for automation. Automation can allow you to monitor the status of sysplex distributor control connections to non-z/OS targets.

Example

EZD1971I SYSPLEX DISTRIBUTOR CONTROL CONNECTION TO DESTINATION IP ADDRESS 9.42.105.53 FAILED WITH 
         RETURN CODE 00000468 REASON CODE 00000000

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014