Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
EZD1755I z/OS Communications Server: IP Messages Volume 2 (EZB, EZD) SC27-3655-01 |
|
EZD1755I Transform transform_name local_attribute_name attribute
value local_attibute_value in local proposal local_proposal_number does
not match remote_attribute_name attribute value remote_attibute_value in
remote proposal remote_proposal_number ExplanationThe Internet Key Exchange (IKE) daemon was unable to accept a proposal because the local and remote IKEv2 Security Association (SA) transform attribute values were not the same. IKE daemon processing continues to the next proposal. If no proposals are accepted, the SA negotiation fails. This failure is indicated by message EZD0985I, EZD1021I, or EZD1022I being issued later in syslog. In the message text:
System actionIKE daemon processing continues. Operator responseContact the system programmer. System programmer responseIf the proposal with the mismatch is the one that should be accepted, notify the administrator of the remote and local security endpoints about the mismatch specification and ask that the configuration be updated with correct values. If the proposal with the mismatch is not the one that should be accepted, you can ignore message EZD1755I. See the information about Policy Agent and policy applications in z/OS Communications Server: IP Configuration Reference for more information about configuring policy. User responseNone. Problem determinationNone. Sourcez/OS® Communications Server TCP/IP: IKE daemon ModuleIKEv2SAAttribute.cpp Routing code11 Descriptor code7 AutomationThis message is output to the syslog. Example
|
Copyright IBM Corporation 1990, 2014
|