If you enter 'C' to select a version to be compared with other
member versions, the SCLM Audit and Version Utility - Compare Panel,
shown in Figure 1, is displayed. Information
about the selected version is shown in the top section of the panel.
The bottom section of the panel lists all the matching versions of
the member that were included in the initial version selection results.
Member versions are considered matching when the Member and Type fields
are the same. If the Hierarchy View option was selected on the SCLM
Audit and Version Utility - Entry Panel, member versions in different
groups appear on this list and can be compared.
Figure 1. SCLM Audit and Version Utility
- Compare Panel (FLMVSC#P) FLMVSC#P SCLM Audit and Version Utility - Compare Panel Row 1 from 32
SCLM Library:
Version . . : SLMTEST7.DEVELOP.ASM(JJMSCPR)
Version Date : 2002/04/12
Version Time : 11:54:23
Sequence
Compare Type Listing Type Numbers
1 1. File 1 1. Delta 1 1. BLANK
2. Line 2. CHNG 2. SEQ
3. Word 3. Long 3. NOSEQ
4. Byte 4. OVSUM 4. COBOL
Listing DS Name
Action Action Action
S Member Group Type Reason Date Time Userid V
- -------- -------- -------- -------- ---------- -------- -------- -
JJMSCPR DEVELOP ASM PROMOTE 2002/06/17 13:56:07 JPHILP #
JJMSCPR DEVELOP ASM PROMOTE 2002/04/17 12:49:34 JPHILP #
Command ===> Scroll ===> PAGE
F1=Help F2=Split F3=Exit F7=Backward F8=Forward F9=Swap
F12=Cancel
The fields for the panel shown in Figure 1 are:
- Version
- Displays the full name of the selected member version.
- Version Date
- The date on which the selected member version was written.
- Version Time
- The time at which the selected member version was written.
- Compare Type
- Specifies the granularity of the comparison, ranging from entire
member to member (File) comparison down
to single Byte differences. Line compare
is useful for source data. Word compare
is most useful for text data.
- Listing Type
- Specifies the context scope of the listing report. You can get
a listing with summary information only (OVSUM),
single line differences between files (Delta),
differences plus or minus the five unchanged lines before and after
changed lines (CHNG), or a listing that
includes all of the lines in both files (Long).
- Sequence numbers
- Specifies whether sequence numbers in the compared files are to
be ignored or treated as data. Choose SEQ to
ignore differences in standard sequence number columns 72 through
80 for FB LRECL 80 members. Choose NOSEQ to
treat all columns in the files as data. Choose COBOL to
ignore differences in columns 1 through 8 of the data. Choose Blank to
cause SuperC to ignore standard sequence number columns if the data
set is FB 80 or VB 255. Otherwise, the comparison processes these
columns as data.
- Listing DS Name
- The data set into which the compare listing is written. You can
preallocate this data set, or let ISPF create one for you. If this
data set is partitioned, you must specify a member name.
To the left of each version listed is a space for entering the S line
command. This command selects the version against which you want to
compare the currently selected member version. You can only select
one of the listed versions.
Note: More sophisticated comparisons can be done using the ISPF Option
3.13, SuperC Compare Utility.