PI80407: ATTRIBUTES IN MODULE ARE NOT EDITABLE VIA DWA, WHEN PARENT FOLDER IS SET TO READ ONLY

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When folder containing a module is set to be Read-Only, but
    module has sufficient permissions to a user, system created
    attributes like Object Heading, Object Text are not editable via
    DOORS Web Access. The attribues are editable via DOORS client.
    Steps to reproduce:
    - Create a Module A inside a folder
    - Assign read-only access to Everyone for the folder
    - Assign RMCDA access to User A, for the module, with Everyone
    Else set to be Read-only
    - Now, login to DOORS Web Access as User A, and open Module A
    - Change the mode to Edit Mode
    - Option to edit Object Heading, Object Text or Object Short
    Text is not seen
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users/environments affected.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When folder containing a module is set to be Read-Only, but  *
    * module has sufficient permissions to a user, system created  *
    * attributes like Object Heading, Object Text are not editable *
    * via DOORS Web Access. The attribues are editable via DOORS   *
    * client.                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    DWA Interop fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.6.1.9 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI80407

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-24

  • Closed date

    2017-12-19

  • Last modified date

    2017-12-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI80407

Modified date: 19 December 2017