IBM Support

PI74827: DOORS REQIF PACKAGE FROM DNG IN DOORS DOES NOT CREATE LINK MODULE OF CORRECT NAME.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • ReqIF package from DNG in DOORS does not create link module of
    correct name.
    
    Steps to reproduce:
    1. Create two modules (System & Subsytem) and a link module
    (satisfies) in DOORS.
    
    2. Create ReqIF package containing  the above modules with all
    data locked in Subsystem module.
    
    3. Import ReqIF package into DNG.
    
    4. Create some 'satisifies' links between System & Subsytem
    modules in DNG.
    
    5.  Export the ReqIF package from DNG with the option selected
    to
    include links
    
    6. Import the ReqIF packgae from DNG back into the DOORS
    project.
    
    In the import folder, the link module is created with the name
    'DOORS Links' NOT "satisfies"
    
    7. Run the merge process.
    
    8. Links are not included in the merged data
    
    Problem 1 - 'DOORS Links' is created rather than creating the
    'satisfies' link module during the import (step 6).
    
    Workaround: rename 'DOORS Links' to 'satisfies' prior to running
    the merge then the links are merged into the "satisfies" link
    module.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users/environments affected.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ReqIF package from DNG to DOORS does not create link module  *
    * of correct name.                                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.6.1.9 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI74827

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    952

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-12

  • Closed date

    2017-12-21

  • Last modified date

    2017-12-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5.2

Reference #: PI74827

Modified date: 21 December 2017