Error description

  • Steps to reproduce:
    - Create a module and set it up for sharing
    - Enable Requirements Change Management on the module
    - Open the module in Shareable Edit mode and make few changes
    - Save changes and send RCR for review
    - Once RCR is approved in CM application, open the module again
    - Perform Apply operation and choose to create a baseline
    
    Apply operation is successful, however baseline is not created.
    DOORS shows the following message:
    Can not create baseline on module <name of module> because it is
    not in exclusive edit mode.
    

Local fix

  • Perform the baseline operation separately, after RCR is applied
    on the module
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of DOORS CM functionality.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * To reproduce:                                                *
    * 1. Create a module and set it up for sharing                 *
    * 2. Enable Requirements Change Management on the module       *
    * 3. Open the module in Shareable Edit mode and make few       *
    * changes                                                      *
    * 4. Save changes and send RCR for review                      *
    * 5. Once RCR is approved in CM application, open the module   *
    * again                                                        *
    * 6. Perform Apply operation and choose to create a baseline   *
    *                                                              *
    * The apply operation is successful, however baseline is not   *
    * created.                                                     *
    *                                                              *
    * Instead DOORS shows the following message "Can not create    *
    * baseline on module <name of module> because it is not in     *
    * exclusive edit mode"                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This has been resolved in the 9614 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI41827

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    960

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-27

  • Closed date

    2015-10-23

  • Last modified date

    2015-10-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.6

Reference #: PI41827

Modified date: 23 October 2015