When ERDS is almost full, the recording routines sense it and issue a message. Run EREP with the parameters required to clear the ERDS (only MVS and VSE use IFCOFFLD). Important: This EREP run may request
a system summary; but it should always include ACC=Y and ZERO=Y, to
write the contents of the ERDS to another file and to clear the ERDS
so the recording routines can write more records to it.