Start of change

CPO3033W   Unsuccessful command completion at CPC name. Reason number

Explanation

The Provisioning Manager detected that a command failed that involved removing active temporary resources from the referenced CPC. Such changes may be performed as a result of a DEACTIVATE RESOURCE or ACTIVATE RESOURCE commands. For the meaning of the reason codes, see IBM z Systems Application Programming Interfaces, SB10-7164.

User response

Check the reason code and correct the problem. If the removal of active temporary resources was initiated manually, you can issue the command again. If the command was initiated by the Provisioning Manager, the missing resource adjustment will be detected and the Provisioning Manager continues managing the CPC, which will result in retrying the failed operation when that is still appropriate.

End of change