z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


BLWH0001E

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

BLWH0001E
AutoIPL policy is not active.

Explanation

CHECK(check_owner,check_name) found no active AutoIPL policy. IBM® suggests activating an AutoIPL policy using a DIAGxx parmlib member. Installations can activate the AutoIPL function so that the system will take predefined actions automatically when it is about to enter certain disabled wait states. Actions can be to re-IPL z/OS®, take a stand-alone dump (SADMP), or take a SADMP and have SADMP re-IPL z/OS when it has finished.

System action

The system continues processing.

Operator response

Report this problem to the system programmer.

System programmer response

Specify an AutoIPL policy using a DIAGxx parmlib member and activate it by issuing a SET DIAG=xx operator command.

Problem determination

N/A

Module

BLWHCCHK

Source

Loadwait/Restart

Reference Documentation

See DIAGxx in z/OS MVS Initialization and Tuning Guide for more information on how to set an AutoIPL policy. See z/OS MVS Planning: Operations for more information on how to exploit the Automatic IPL function.

Automation

N/A

Routing Code

See note 35.

Descriptor Code

See note 1.