z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ATR149I

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

ATR149I
RRS INITIALIZATION HAS FAILED. SYSTEM LOGGER IS UNAVAILABLE FOR THIS IPL.

Explanation

In its attempt to connect to log streams, RRS has determined that system logger services will not be available for the duration of this IPL.

System action

RRS initialization backs out all processing and brings down the RRS address space.

Operator response

Inform your system programmer.

System programmer response

If RRS processing is required, system logger must be available. Investigate and resolve the logger problem, then re-IPL the systems and restart RRS.

Module

ATRAMINI

Source

Resource recovery services (RRS)

Routing Code

1,2

Descriptor Code

12

Go to the previous page Go to the next page