z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


048

z/OS MVS System Codes
SA38-0665-00

048

Explanation

A subsystem address space supported by advanced communications function/telecommunications access method (ACF/TCAM) had an error condition. An ACF/TCAM subsystem has determined that recovery could not occur. The subsystem abnormally ends. Register 0 contains one of the following failure codes:
Code
Explanation
001
The request parameter list (RPL) address was incorrect when the subsystem interface was not running with authorized path.
002
An abnormal end occurred before the subsystem was notified of function recovery routines (FRR) recovery.

System action

Restart the subsystem.

System programmer response

Format the SVC dump with the interactive problem control system (IPCS). Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Programmer response

Print the SVC dump, which was stored in the SYS1.DUMP data set.

Source

Teleprocessing

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014