Use the fields on the Mountable Optical Volume Selection Entry
Panel to set up basic selection criteria: the serial numbers of the
volumes to include in the list and the source ISMF uses to generate
the list.
Figure 1 shows the Mountable Tape Volume
Selection Entry Panel with its default values.
Figure 1. Mountable
Tape Volume Selection Entry Panel Panel Utilities Help
------------------------------------------------------------------------------
MOUNTABLE TAPE VOLUME SELECTION ENTRY PANEL
Command ===>
Select Source to Generate Volume List . . 2 (1 - Saved list, 2 - New list)
1 Generate from a Saved List
List Name . .
2 Generate a New List from Criteria Below
Volume Serial Number . . . * (fully or partially specified)
Library Name . . . . . . . * (fully or partially specified)
Storage Group Name . . . . * (fully or partially specified)
Enter "/" to select option _ Respecify View Criteria
_ Respecify Sort Criteria
Use ENTER to Perform Selection;
Use HELP Command for Help; Use END Command to Exit.
Here is an overview of each field:
- Select Source to Generate Volume List
- In this mandatory field, indicate whether to create a new list
or use a list previously saved with the SAVE command. Option 2 is
the default.
- Option
- Meaning
- 1
- Use a list previously saved with the SAVE command. When selecting
this option, you must complete the field under Generate from
a Saved List. See Saving a Copy of the List for
more information.
- 2
- Create a new list. When selecting this option, you must complete
the fields under Generate a New List from Criteria Below.
- 1 Generate from a Saved List
- Complete the following fields if you selected option 1 for Select
Source to Generate Volume List:
- List Name
- Enter the name
of a list previously saved with the SAVE command. The list name can
be up to eight alphanumeric characters long and must follow naming
conventions for members of partitioned data sets.
- 2 Generate a New List from Criteria Below
- Complete the following fields if you selected option 2 for Select
Source to Generate Volume List:
- Volume Serial Number
- Enter a
full or partial serial number of the volume or volumes to include
in the list. Use this field to restrict the list to volumes with a
specific volume serial number or range of volume serial numbers.
Restriction: If
the cartridge containing the volume is to be mounted on an IBM® TotalStorage™ Enterprise Automated
Tape Library (3495), do not use special characters and national characters
to define the volume serial number.
To include a single volume,
enter a fully qualified volume serial number of one to six characters:
Volume Serial Number ===> SYS001
To
include a range of volumes, enter a partially qualified volume serial
number by using an asterisk or percent sign as a global file-name
character. For example:
Volume Serial Number ===> SYS*
You
can use up to two asterisks as global file-name characters. For example,
for tape volsers numbered 800100 through 890599, you can enter the
following to include only those that end in 430 through 439:
Volume Serial Number ===> 8*043*
Restriction: Do not use two asterisks next
to each other (**).
Use a single asterisk to specify
all mounted volumes that fit your other selection criteria:
Volume Serial Number ===> *
- Library Name
- Enter
the one- to eight-character name of an automated tape library.
Specify
the library name the same way you specify the volume serial number,
but start the name with a non-numeric character. Do not use special
characters.
- Storage Group Name
- Enter the
one- to eight-character name of an SMS storage group. Specify the
storage group name the same way you specify the volume serial number,
but start the name with an alphabetic or national character.
To
select volumes that belong to a blank storage group, specify ' ' in
this field.
Volumes assigned to a blank storage group are
in an SMS-managed tape library and should be distinguished from non-SMS-managed
tape volumes that are not supported by the Mountable Tape Volume Application.
- Respecify View Criteria
- In
this mandatory field, you can choose to display the Mountable Tape
Volume View Entry Panel to select the columns and the order of the
columns to display on the list panel. If you leave VIEW criteria blank,
the Mountable Tape Volume List Panel is displayed using the default
VIEW criteria (display all columns in alphabetical order) or the criteria
that were last specified to ISMF, if any. This may result in a restricted
view.
- Option
- Meaning
- /
- Display the Mountable Tape Volume View Entry Panel before creating
the volume list.
- blank
- Do not display the Mountable Tape Volume View Entry Panel before
creating the volume list. Blank is the default.
- Respecify Sort Criteria
- In
this mandatory field, you can choose to display the Mountable Tape
Volume Sort Entry Panel to sort the resulting volume list according
to the values in its data columns.
- Option
- Meaning
- /
- Display the Mountable Tape Volume Sort Entry Panel before creating
the volume list.
- blank
- Do not display the Mountable Tape Volume Sort Entry Panel before
creating the volume list. Blank is the default.
For example, sort the list by specifying ascending
order for the values in the volume serial column. In the resulting
volume list, the volumes sort in numeric order by volume serial number.
If
you specify Y for both VIEW and SORT criteria, the Mountable Tape
Volume View Entry Panel is displayed, followed by the Mountable Tape
Volume Sort Entry Panel.