The DB2 pureScale Feature is supported on any RoCE and QDR cable and switch that is supported by the Power 7 servers.
Server | Minimum Required Platform Firmware level | InfiniBand network adapter, GX Dual-port 12x Channel Attach - DDR InfiniBand Channel adapter | InfiniBand Channel conversion cables |
---|---|---|---|
IBM POWER7® 795 (9119-FHB) * | AH720_102 or higher | Feature Code 1816 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 780 (9179-MHB) * | AM720_102 or higher | Feature Code 1808 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 780 (9179-MHC) * | AM740_042 or higher | Feature Code 1808 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 770 (9117-MMB) * | AM720_102 or higher | Feature Code 1808 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 770 (9117-MMC) * | AM740_042 or higher | Feature Code 1808 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 750 (8233-E8B) | AL730_049 or higher | Feature Code 5609 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 740 (8205-E6C) | AL720_102 or higher | Feature Code EJ04 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 740 (8205-E6B) | AL720_102 or higher | Feature Code 5615 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 730 (8231-E2B) | AL720_102 or higher | Feature Code 5266 | 4x to 4x cables (Feature Code 3246) |
IBM POWER7 720 (8202-E4C) | AL720_102 or higher | Feature Code EJ04 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 720 (8202-E4B) | AL720_102 or higher | Feature Code 5615 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER7 710 (8231-E2B) | AL720_102 or higher | Feature Code 5266 | 4x to 4x cables (Feature Code 3246) |
IBM POWER6® 595 (9119-FHA) | EH350_071 or higher | Feature Code 1816 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
IBM POWER6 550 Express (8204-E8A) | EL350_071 or higher | Feature Code 5609 | 12x to 4x (Feature Code 1828, 1841, or 1854) |
Server | Minimum Required Platform Firmware level | PCle2 Dual port QDR InfiniBand Channel adapter |
---|---|---|
IBM POWER7 780/HE (9179-MHC) | AM740_042_042 | PCIe2 2-port 4X InfiniBand QDR Adapter (Feature code: 5285) |
IBM POWER7 770/MR (9117-MMC) | AM740_042_042 | PCIe2 2-port 4X InfiniBand QDR Adapter (Feature code: 5285) |
IBM POWER7 740 2S (8205-E6C with optional low-profile slots) | AL740_043_042 | PCIe2 2-port 4X InfiniBand QDR Adapter (Feature code: 5285), or PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature code: 5685), or both |
IBM POWER7 740 (8205-E6B) with Newcombe (optional low-profile Gen2 slots) | AL720_102 | PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature code: 5685) |
IBM POWER7 710 (8231-E1C) | AL740_043_042 | PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature Code: 5685) |
IBM POWER7 720 (8202-E4B) | AL730_066_035 | PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature Code: 5685) |
IBM POWER7 720 (8202-E4C) | AL740_043_042 | PCIe2 2-port 4X InfiniBand QDR Adapter (Feature code: 5285), or PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature code: 5685), or both |
IBM POWER7 730 2S (8231-E2C) | AL740_043_042 | PCIe2 Low Profile 2-port 4X InfiniBand QDR Adapter (Feature code: 5283) in the PCIe Newcombe Riser Card (Feature Code: 5685) |
Server | Minimum Required Platform Firmware level | PCIe Support for RoCE network adapters |
---|---|---|
IBM POWER7 780/HE (9179-MHC) | AM740_042_042 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) |
IBM POWER7 770/MR (9117-MMC) | AM740_042_042 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) |
IBM POWER7 780/HE (9179-MMD) | AM760_034_034 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) |
IBM POWER7 770/MR (9117-MMD) | AM760_034_034 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) |
IBM POWER7 720 1S (8202-E4C with optional low-profile slots) | AL740_043_042 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) PCIe2 Low Profile 2-Port 10GbE RoCE SFP+ Adapter (Feature code EC27) (Copper) in the PCIe Newcombe Riser Card (Feature code 5685) PCIe2 Low Profile 2-Port 10GbE RoCE SR Adapter (Feature code EC29) (Optical) in the PCIe Newcombe Riser Card (Feature code 5685) |
IBM POWER7 740 2S (8205-E6C with optional low-profile slots) | AL740_043_042 | PCIe2 2-Port 10GbE RoCE SFP+ Adapter (Feature
code EC28) (Copper) PCIe2 2-Port 10GbE RoCE SR Adapter (Feature code EC30) (Optical) PCIe2 Low Profile 2-Port 10GbE RoCE SFP+ Adapter (Feature code EC27) (Copper) in the PCIe Newcombe Riser Card (Feature code 5685) PCIe2 Low Profile 2-Port 10GbE RoCE SR Adapter (Feature code EC29) (Optical) in the PCIe Newcombe Riser Card (Feature code 5685) |
IBM POWER7 710 1S (8231-E1C) | AL740_043_042 | PCIe2 Low Profile 2-Port 10GbE RoCE SFP+
Adapter (Feature code EC27) (Copper) PCIe2 Low Profile 2-Port 10GbE RoCE SR Adapter (Feature code EC29) (Optical) |
IBM POWER7 730 2S (8231-E2C) | AL740_043_042 | PCIe2 Low Profile 2-Port 10GbE RoCE SFP+
Adapter (Feature code EC27) (Copper) PCIe2 Low Profile 2-Port 10GbE RoCE SR Adapter (Feature code EC29) (Optical) |
IBM Flex System® p260 Compute Node (7895-22X) | AF763_042 | EN4132 2-port 10Gb RoCE Adapter (Feature code EC26) |
IBM Flex System p260 Compute Node (7895-23X) | AF763_042 | EN4132 2-port 10Gb RoCE Adapter (Feature code EC26) |
IBM Flex System p460 Compute Node (7895-42X) | AF763_042 | EN4132 2-port 10Gb RoCE Adapter (Feature code EC26) |
10GE Cable Information:
1 meter | 3 meter | 5 meter | |
---|---|---|---|
Feature Code number | EN01 | EN02 | EN03 |
1 meter | 3 meter | |
---|---|---|
Feature Code number | EB2B | EB2H |
1 meter (copper) | 3 meter (copper) | 5 meter (copper) | 10 meter (optical) | 30 meter (optical) | |
---|---|---|---|---|---|
Feature Code number | 3287 | 3288 | 3289 | 3290 | 3293 |
InfiniBand switch | Intel model number | Number of ports | Type | Required rack space |
---|---|---|---|---|
IBM 7874-024 | 9024 | 24 | 4x DDR InfiniBand Edge Switch | 1U |
IBM 7874-040 | 9040 | 48 | 4x DDR InfiniBand Fabric Director Switch | 4U |
IBM 7874-120 | 9102 | 128 | 4x DDR InfiniBand Fabric Director Switch | 7U |
IBM 7874-240 | 9240 | 288 | 4x DDR InfiniBand Fabric Director Switch | 14U |
IBM 7874-036 | 12200 | 36 | QDR InfiniBand Switch | 1U |
IBM 7874-072 | 12800-040 | 72 | QDR InfiniBand Switch | 5U |
IBM 7874-324 | 12800-180 | 324 | QDR InfiniBand Switch | 14U |
DDR and QDR InfiniBand network switch types cannot be intermixed. The same type of switch, adapter and cables must be used in a cluster. A server using a DDR IB adapter must use a DDR type switch and the corresponding cables. A server using a QDR IB adapter must use a QDR type switch and the corresponding cables.
IBM Validated Switch |
---|
Blade Network Technologies® RackSwitch™ G8124 |
Juniper Networks QFX3500 Switch |
A minimum of three shared file systems are required, each on a separate physical disk. A fourth shared disk is recommended to configure as the DB2 cluster services tiebreaker disk.
AIX version | Technology Level | Minimum Service Pack (SP) level | Required uDAPL level | uDAPL APAR | AIX APAR |
---|---|---|---|---|---|
AIX 6.1 | 6 | 5 | 6.1.6.15 | IV01781 (included in SP6)* | |
AIX 6.1 | 7 | 1 | 6.1.7.0 | ||
AIX 6.1 | 7 | 3 | 6.1.7.1 | ||
AIX 6.1 | 7 | 5 | 6.1.7.15 | ||
AIX 6.1 | 8 | 1 | 6.1.8.0 | IV35889* | IV34702 (included in SP2) |
AIX 6.1 | 9 | 1 | 6.1.9.01 | ||
AIX 7.1 | 0 | 3 | 7.1.0.15 | IV02136 (included in SP4)* | |
AIX 7.1 | 1 | 1 | 7.1.1.0 | ||
AIX 7.1 | 1 | 3 | 7.1.1.2 | ||
AIX 7.1 | 1 | 5 | 7.1.1.15 | ||
AIX 7.1 | 2 | 1 | 7.1.2.0 | IV35894* | IV34702 (included in SP2) |
AIX 7.1 | 3 | 1 | 7.1.3.01 |
AIX version | Technology Level | Minimum Service Pack (SP) level | Required uDAPL level | uDAPL APAR | AIX APAR |
---|---|---|---|---|---|
AIX 6.1 | 7 | 5 | 6.1.7.15 | IV263831 | |
AIX 6.1 | 8 | 1 | 6.1.8.0 | IV35889* | IV34702 (included in SP2) |
AIX 6.1 | 9 | 1 | 6.1.9.05 | ||
AIX 7.1 | 1 | 5 | 7.1.1.15 | IV263842 | |
AIX 7.1 | 2 | 1 | 7.1.2.0 | IV35894* | IV34702 (included in SP2) |
AIX 7.1 | 3 | 1 | 7.1.3.05 |
AIX version | Technology Level | Minimum Service Pack (SP) level | Required uDAPL level | uDAPL APAR | AIX APAR |
---|---|---|---|---|---|
AIX 6.1 | 7 | 3 | 6.1.7.2 (updated with IV20240) | IV20240 | |
AIX 6.1 | 7 | 5 | 6.1.7.15 | ||
AIX 6.1 | 8 | 1 | 6.1.8.0 | IV35889* | IV34702 (included in SP2) |
AIX 6.1 | 9 | 1 | 6.1.9.01 | ||
AIX 7.1 | 1 | 3 | 7.1.1.2 (updated with IV20241) | IV20241 | |
AIX 7.1 | 1 | 5 | 7.1.1.15 | ||
AIX 7.1 | 2 | 1 | 7.1.2.0 | IV35894* | IV34702 (included in SP2) |
AIX 7.1 | 3 | 1 | 7.1.3.01 |