Several SAS subsystem configurations are supported on the 8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD systems.
The configuration you use depends on the combination of SAS features that you have installed on your system. The following table provides an overview of the features and related configurations.
SAS subsystem configuration | 175 MB Cache RAID - Dual IOA enablement card (FC 5662) | External SAS components | SAS port cables | SAS cables | Limitations |
---|---|---|---|---|---|
Two-way split backplane | No Note: The two embedded
SAS adapters report as CCIN 57C7.
|
None | None | Not applicable |
|
Three-way split backplane | No Note: The two embedded SAS adapters
report as CCIN 57C7.
|
Dual-x4 SAS adapter (FC 5901: CCIN 57B3) | Internal SAS port (FC 1815): SAS cable for three-way split backplane | AI cable (FC 3679): Adapter to internal drive 1 meter |
|
Dual storage IOA configuration using internal disk drives | Yes Note: The internal dual RAID IOA adapters
report as CCIN 57CF.
|
None | None | Not applicable |
|
Dual storage IOA configuration using internal disk drives and external disk enclosure | Yes Note: The internal dual RAID IOA adapters
report as CCIN 57CF.
|
Requires an external disk enclosure (FC 5886 or FC 5887) | Internal SAS port (FC 1819): SAS cable assembly for connecting to an external SAS drive enclosure |
|
Only HDDs are supported. |