IBM Support

PM55568: COMMAND FLOW EXITS USE L8 TCB WHEN CICS CONCURRENCY ATTRIBUTE IS SET TO REQUIRED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The command flow exits are using L8 TCBs incorrectly
    with the new concurrency attribute of REQUIRED that was
    introduced in CICS Transaction Server v4.2.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: CICS IA 3.2 users who exploit the CICS IA    *
    *                 Command Flow Data.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS IA presents TCB switching process  *
    *                      incorrectly for the Command Flow data.  *
    *                      Columns TCBMODE, PREV_TCBMODE and       *
    *                      BEFORE_MODESWITCH of                    *
    *                      the CIU_CMDFLOW_DATA table currently    *
    *                      do not show all the TCB swaps that can  *
    *                      happen. CICS IA can not detect all TCB  *
    *                      swaps.                                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF and perform HOLD ACTION.       *
    ****************************************************************
    To fix this, two columns were added to CIU_CMDFLOW_DATA table:
    TCB_SWITCH_BEFORE_COUNT The TCB mode switch count. The
                            value of this field is determined
                            before the start of the command
                            and is obtained from CICS
                            Monitoring Domain data.
    TCB_SWITCH_AFTER_COUNT  The TCB mode switch count. The
                            value of this field is determined
                            after the completion of the
                            command and is obtained from
                            CICS Monitoring Domain data.
    Note:
    1.The TCB_SWITCH_BEFORE_COUNT and TCB_SWITCH_AFTER_COUNT fields
      represent the accumulated value of count for CICS
      Dispatcher change-TCB mode request issued from start user's
      task to moment of CICS Monitoring Domain statistics data
      enquiring.
    2.A value of -1 in these fields indicates that the TCB switch
      counter data is not available due to the CICS Monitoring
      Domain being deactivated during the command flow collection.
    

Problem conclusion

  • Code has been added.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM55568

  • Reported component name

    CICS INTER ANAL

  • Reported component ID

    5655U8600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-10

  • Closed date

    2012-10-11

  • Last modified date

    2012-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PM65421 UK82589 UK82590 UK82591

Modules/Macros

  •    CIUACM00 CIUACM10 CIUACM20 CIUACM30 CIUACM31
    CIUACM32 CIUACM40 CIUACM60 CIUACM61 CIUACM70 CIUACM71 CIUATM03
    CIUBCXPI CIUCINCE CIUCNFG2 CIUICDUF CIUJALT1 CIUJLCPY CIUMSGE
    CIUMSGK  CIURCMDF CIUSCTR1 CIUSCTR2 CIUUDBC  CIUUDB4  CIUUPDB5
    CIUU044  CIUU045  CIUVERUP CIUXACE2 CIUXACL2 CIUXACO2 CIUXACO3
    CIUXACR2 CIUXACR3 CIUXACT1 CIUXCCD1 CIUXCCE1 CIUXCCF1 CIUXCCF2
    CIUXCCGA CIUXCCI1 CIUXCCL1 CIUXCCOA CIUXCCOE CIUXCCOG CIUXCCOL
    CIUXCCOW CIUXCCO1 CIUXCCP1 CIUXCCP2 CIUXCCRS CIUXCCR1 CIUXCCS1
    CIUXCCW1 CIUXDB2A CIUXIMSA CIUXMQMA CIUXNATA CIUXNQED CIUZCCBA
    CIUZCCBB CIUZCCB1 CIUZCCFA CIUZCCF1 CIUZCCIC CIUZCCIR CIUZCCI1
    CIUZCCML CIUZCCMS CIUZCCM1 CIUZCCOA CIUZCCOC CIUZCCOE CIUZCCOG
    CIUZCCOL CIUZCCOQ CIUZCCOR CIUZCCOS CIUZCCOW CIUZCCOY CIUZCCO1
    CIUZCCXX CIUZCCX1 CIU53XPI CIU62XPI CIU63XPI CIU64XPI CIU65XPI
    CIU66XPI CIU67XPI
    

Publications Referenced
SC34721100    

Fix information

  • Fixed component name

    CICS INTER ANAL

  • Fixed component ID

    5655U8600

Applicable component levels

  • R32E PSY UK82590

       UP12/10/16 P F210

  • R32K PSY UK82591

       UP12/10/16 P F210

  • R320 PSY UK82589

       UP12/10/16 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: