Fixes are available
November 2010 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
November 2010 PTF for XL C Enterprise Edition for AIX, V9.0
March 2011 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
March 2011 PTF for XL C Enterprise Edition for AIX, V9.0
July 2011 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
December 2011 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
March 2012 PTF for XL C Enterprise Edition for AIX, V9.0
March 2012 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
August 2010 PTF for XL C/C++ Enterprise Edition for AIX, V9.0
August 2010 PTF for XL C Enterprise Edition for AIX, V9.0
July 2011 PTF for XL C Enterprise Edition for AIX, V9.0
December 2011 PTF for XL C Enterprise Edition for AIX, V9.0
APAR status
Closed as program error.
Error description
When generating an assembler language file with the -S compiler option, the compiler is encountering an internal error: $ xlC -S -c foo.C xlC: 1501-230 (S) Internal compiler error; please contact your Service Representative Removing -S and compiling to an object file is successful, but attempting to disassemble the object file with the compiler's 'dis' utility causes a segmentation fault: $ /usr/vac/exe/dis foo.o Segmentation fault $
Local fix
Use the -qlist listing file for assembly information
Problem summary
PROBLEM DESCRIPTION: Internal Compiler Error when compiling with C++ and the -S option. USERS AFFECTED: C++ users of the -S option using templates that produce long symbol names.
Problem conclusion
Increased buffer sizes to greater than the longest possible symbol names, thereby correcting the error.
Temporary fix
Comments
APAR Information
APAR number
IZ73424
Reported component name
XLC C++ AIX
Reported component ID
5724S7100
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-25
Closed date
2010-07-30
Last modified date
2010-07-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
XL C AIX
Fixed component ID
5724S7000
Applicable component levels
Document Information
Modified date:
07 October 2021