A fix is available
APAR status
Closed as program error.
Error description
Problem Description: Tivoli Monitoring agents fail to connect to the Monitoring server without attempting to retry the failing bind operation using the next derived port in the range of ports. This results in an agent connection failure with no attempt to retry the connect. This defect is observed most frequently on z/OS but can occur on all Tivoli Monitoring supported platforms. Detailed Recreation Procedure: This can be recreated by configuring Tivoli Monitoring agents on z/OS and watching connection establishment behavior when the first derived port is used by SYSPLEX or other products. The observed behavior changes when the reservation is moved to the second derived port and the agents are re-started. Related Files and Output: RAS1 tracing with KDC_DEBUG=Y and KDE_DEBUG=Y will show IP.PIPE and IP.SPIPE port allocations retry local binds which fail with error EADDRINUSE. When the error is not EADDRINUSE, no attempt is made to retry the bind with the next available derived port.
Local fix
Use SKIP: to avoid the offending port(s)
Problem summary
IP.PIPE PORT ALLOCATION fails correctly for error EADDRINUSE, and fails incorrectly for error EADDRNOTAVAIL.
Problem conclusion
Tivoli Monitoring agents fail to connect to the Monitoring server without attempting to retry the failing bind operation using the next derived port in the range of ports. This results in an agent connection failure with no attempt to retry the connect. This defect is observed most frequently on z/OS but can occur on all Tivoli Monitoring supported platforms. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0003
Temporary fix
The code was changed to respond correctly to both error conditions, EADDRINUSE and EADDRNOTAVAIL.
Comments
APAR Information
APAR number
IV62585
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-17
Closed date
2014-07-22
Last modified date
2014-08-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R630 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCTLMP","label":"ITM Tivoli Enterprise Mgmt Server V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
08 August 2014