IBM Support

IV21708: CEC AGENT MANUAL NEEDS TO CLARIFY "CFGSVC" COMMAND SYNTAX FOR USE ON VIOS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • ENVIRONMENT:
    
    IBM Tivoli Monitoring for System p - CEC Base Agent v6.2.2
    Interim
    Feature 2 running on VIOS 2.2.1
    
    PROBLEM DESCRIPTION:
    
    Documentation for use of "cfgsvc" command to configure ITM_cec
    agent
    service on VIOS is unclear.
    
    The following is documented in the current manual:
    IBM Tivoli Monitoring: CEC Base Agent
    User's Guide
    Version 6.2.2.1
    SC23-5239-07
    In Chapter:
    Requirements and agent-specific installation and configuration
    information for the monitoring agent
    
    Under section:
    Agent-specific installation and configuration -> Configuration
    *******
    VIOS
    Although the CEC agent is now preinstalled on the VIOS V2.2.0.0,
    Fix
    Pack 24, you must configure the CEC Base agent with the cfgsvc
    command.
    cfgsvc ITM_cec -attr hostname=name_or_address1,
    mirror=name_or_address3,
    Restart_On_Reboot=value cec=cec_name
    managing_system=name_or_address2 OR hmcuser@name_or_address2
    DIRECTOR_HOST_ADDRESS=<director_hostname> (optional),
    DIRECTOR_PORT_NUMBER=8422 (optional) DIRECTOR
    _AUTHENTICATION=Yes
    (optional)
    Where:
    ITM_cec
    Name of the monitoring agent.
    name_or_address1
    Either the host name or IP address of the Tivoli Enterprise
    Monitoring
    Server to which ITM_agent_name sends data.
    name_or_address3
    Secondary Tivoli Enterprise Monitoring Server host name or IP
    address.
    cec_name
    Name of the CEC that the agent is monitoring.
    value
    Either TRUE or FALSE as follows:
    TRUE
    ITM_cec restarts when the Virtual I/O Server restarts.
    FALSE
    ITM_cec does not restart whenever the Virtual I/O Server
    restarts.
    name_or_address2
    Either the host name or IP address of the Hardware Management
    Console
    (HMC) attached to the managed system on which the Virtual I/O
    Server
    with the monitoring agent is located.
    hmcuser
    User on the HMC computer (with authority equivalent to
    "hscroot").
    director_hostname
    IBM Systems Director Server to which to navigate using the IBM
    Systems
    Director workspace links.
    Note:
    If hmcuser is not specified, the default user is "hscroot".
    
    Note:  The parameters must be specified in the order indicated.
    *******
    The command syntax for the "cfgsvc" command syntax includes
    commas which
    will result in the ITM_cec agent service not working due to
    invalid
    values for parameters.
    
    The "cfgsvc" command syntax needs to be clarified to remove the
    commas,
    and the (optional) flags from within the actual command syntax.
    
    The above would be clearer if documented as:
    
    ***
    VIOS
    Although the CEC agent is now preinstalled on the VIOS V2.2.0.0,
    Fix
    Pack 24, you must configure the CEC Base agent with the cfgsvc
    command.
    cfgsvc ITM_cec -attr hostname=name_or_address1
    mirror=name_or_address3
    Restart_On_Reboot=value cec=cec_name
    managing_system=hmcuser@name_or_address2
    DIRECTOR_HOST_ADDRESS=<director_hostname>
    DIRECTOR_PORT_NUMBER=8422
    DIRECTOR_AUTHENTICATION=Yes
    Where:
    ITM_cec
    Name of the monitoring agent.
    name_or_address1
    Either the host name or IP address of the Tivoli Enterprise
    Monitoring
    Server to which ITM_cec sends data.
    name_or_address3
    Secondary Tivoli Enterprise Monitoring Server host name or IP
    address.
    cec_name
    Name of the CEC that the agent is monitoring.
    The value of the cec-name can be determined from running the
    following
    command on the HMC and choosing the correct CEC from the list
    that the
    HMC manages:
     lssyscfg -r sys -F name
    value
    Either TRUE or FALSE as follows:
    TRUE
    ITM_cec restarts when the Virtual I/O Server restarts.
    FALSE
    ITM_cec does not restart whenever the Virtual I/O Server
    restarts.
    name_or_address2
    Either the host name or IP address of the Hardware Management
    Console
    (HMC) attached to the managed system on which the Virtual I/O
    Server
    with the monitoring agent is located.
    hmcuser
    User on the HMC computer (with HMC viewer authority).  Defaults
    to
    hscroot if not specified.
    director_hostname
    IBM Systems Director Server to which to navigate using the IBM
    Systems
    Director workspace links.
    
    Note:  The parameters must be specified in the order indicated.
               The following parameters are optional:
                      mirror
                      DIRECTOR_HOST_ADDRESS
                      DIRECTOR_PORT_NUMBER
                      DIRECTOR_AUTHENTICATION
                      hmcuser@ on managing_system parameter
    
    
    RECREATE INSTRUCTIONS: None.
    Additional Keywords:
    IZ73124
    

Local fix

Problem summary

  • The IBM Tivoli Monitoring: CEC Base Agent User's Guide Version
    6.2.2.1 SC23-5239-07 is unclear in documenting the use of the
    "cfgsvc" command to configure ITM_cec agent service on VIOS.
    

Problem conclusion

  • The documentation will be updated in the next release of the
    User's Guide as follows:
    
    In Chapter:
    Requirements and agent-specific installation and configuration
    information for the monitoring agent
    
    Under section:
    Agent-specific installation and configuration -> Configuration
    *******
    VIOS
    
    Although the CEC agent is now preinstalled on the VIOS V2.2.0.0,
    Fix
    Pack 24, you must configure the CEC Base agent with the cfgsvc
    command.
    cfgsvc ITM_cec -attr hostname=name_or_address1
    mirror=name_or_address3
    Restart_On_Reboot=value cec=cec_name
    managing_system=hmcuser@name_or_address2
    DIRECTOR_HOST_ADDRESS=<director_hostname>
    DIRECTOR_PORT_NUMBER=8422
    DIRECTOR_AUTHENTICATION=Yes
    Where:
    ITM_cec
    Name of the monitoring agent.
    name_or_address1
    Either the host name or IP address of the Tivoli Enterprise
    Monitoring
    Server to which ITM_cec sends data.
    name_or_address3
    Secondary Tivoli Enterprise Monitoring Server host name or IP
    address.
    cec_name
    Name of the CEC that the agent is monitoring.
    The value of the cec-name can be determined from running the
    following
    command on the HMC and choosing the correct CEC from the list
    that the
    HMC manages:
     lssyscfg -r sys -F name
    value
    Either TRUE or FALSE as follows:
    TRUE
    ITM_cec restarts when the Virtual I/O Server restarts.
    FALSE
    ITM_cec does not restart whenever the Virtual I/O Server
    restarts.
    name_or_address2
    Either the host name or IP address of the Hardware Management
    Console
    (HMC) attached to the managed system on which the Virtual I/O
    Server
    with the monitoring agent is located.
    hmcuser
    User on the HMC computer (with HMC viewer authority).  Defaults
    to
    hscroot if not specified.
    director_hostname
    IBM Systems Director Server to which to navigate using the IBM
    Systems
    Director workspace links.
    
    Note:  The parameters must be specified in the order indicated.
               The following parameters are optional:
                      mirror
                      DIRECTOR_HOST_ADDRESS
                      DIRECTOR_PORT_NUMBER
                      DIRECTOR_AUTHENTICATION
                      hmcuser@ on managing_system parameter
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV21708

  • Reported component name

    ITM SE SYSP CEC

  • Reported component ID

    5724C04CB

  • Reported release

    622

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-23

  • Closed date

    2012-05-29

  • Last modified date

    2012-05-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
26 August 2022