IBM Support

IC78957: FLASH OF I2-H2 IS PERFORMED EVEN WHEN THE GLOBAL MIRROR PORTION FAILED FULL RECOVERY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When pprc paths are setup for 5 or more source LSS to a single
    target LSS and a Recover or Flash command is run. This will lead
    to a path setup error due to it violates the path rule when
    going in reverse direction: Max 4 target LSSs for 1 source LSS.
    This may cause the data copied to I2 and H2 volumes to be
    inconsistent, since the Flash of I2-H2 is performed even when
    the global mirror failed full recovery due to the path setup
    problem.
    

Local fix

Problem summary

  • FLASH command fails in Global Mirror failover/failback session
    
    because there are more than 4 lss going into a single lss. This
    causes the failover to fail bcause a lss cannot have more than 4
    paths out.This causes 0F51 error which in turn causes the frr to
    fail with 0F85. However, the I2-H2 will still be flashed.
    

Problem conclusion

  • The Flash command will now only flash if the H1-J2 sequence is
    consistent.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC78957

  • Reported component name

    TPC FOR REPLICA

  • Reported component ID

    5608TRM00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-29

  • Closed date

    2014-03-31

  • Last modified date

    2014-03-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC FOR REPLICA

  • Fixed component ID

    5608TRM00

Applicable component levels

  • R420 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMN28","label":"Tivoli Storage Productivity Center for Replication"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date: