A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 12 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. IDI0095W Unexpected condition found * * in IDIDODSN:1004: Process error. * * APAR PM65401 * * 02. Excessive time taken to analyze * * COBOL abend when many base locators * * are processed. * * APAR PM65402 * * 03. Unable to change fault entry prefix * * using the Fault Analyzer ISPF * * interface File->Change Fault * * History File Settings action-bar * * pull-down option. * * APAR PM64341 * * 04. CICS SDUMP panel displays Kernel * * Error registers incorrectly if they * * are flagged as containing 64-bit * * values. * * APAR PM65403 * * 05. CICS SDUMP panel displays PPTE * * CONCURRENCY values incorrectly in * * CICS 4.2 dumps. * * APAR PM65404 * * 06. Abend S0C4 in IEAVENLU+50 when * * Fault Analyzer IDICSVCR is * * FREEMAINed at TCB DETACH. * * APAR PM65405 * * 07. KE_NUM column all 0000 in KE error * * display with a CICS/TS 4.2 dump. * * APAR PM65406 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. A CDE data area size was incorrectly set to 40 bytes. 02. DSA address not passed to COBOL side file functions causes slow running entry point detection. 03. Although the display accepts the change, the history file is not being updated. 04. Fault Analyzer does not check the flag which indicates that registers contain 64-bit values, and therefore formats them as if they contained 32-bit values. 05. CICS 4.2 added a new CONCURRENCY option. Fault Analyzer was not updated to show that new option value. 06. An S0C4 abend can occur if the Fault Analyzer router SVC is FREEMAINed when the TCB that loads it is DETACHed. 07. The required data is now referenced by a 64-bit pointer and this was not being correctly allowed for.
Problem conclusion
01. The CDE data area size has been changed to 32 bytes. 02. DSA address now passed to COBOL side file functions. 03. The history file is now being updated. 04. Fault Analyzer has been changed to use 64-bit formatting when the 64-bit flag is set. 05. Fault Analyzer has been changed to present the correct CONCURENCY value - QUASIRENT/THREADSAFE/REQUIRED. 06. The CDE use count error is corrected. 07. The 64-bit pointer is now correctly allowed for.
Temporary fix
Comments
APAR Information
APAR number
PM64218
Reported component name
FAULT ANALYZER
Reported component ID
5655W6900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2012-05-09
Closed date
2012-06-08
Last modified date
2012-07-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK79416
Modules/Macros
IDICASUB IDICCFND IDICOPYR IDICSVCR IDIDA IDIEDPIE IDIEEDE IDIGMAIN IDIGUIP IDIHE003 IDIHIBMM IDIHPMSG IDIMCICS IDINDEX IDIPBRWS IDIPDDIR IDIPDSCU IDIPHI06 IDIPH112 IDISAMAN IDISCJST IDISDB2P IDISDB2S IDISFESK IDISFPEX IDISIFND IDISJLD IDISLKUP IDISLOG IDISMAIN IDISREG IDISTIME IDISUPDI IDISVIEW IDIUGPDF IDIUTIL IDIXFA
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655W6900
Applicable component levels
RC10 PSY UK79416
UP12/06/23 P F206
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information