IBM Support

OA60494: ABEND0C4 IN ERBMFICA UJ04163 WHEN ICSF APAR OA59593 IS NOT APPLIED. 20/11/16 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 in ERBMFICA at level UJ04163
    The ABEND0C4 in ERMMFICA UA04163 +x'620' occurs trying
    to access an entry past the end of the DACC control block.
    
    PE INFORMATION:
    USERS AFFECTED:
    For ICSF FMID HCR77D1:APAR OA59330 applied without prereq
    OA59593
    For ICSF FMID HCR77D0:APAR OA59330 applied
    
    USER IMPACT:
    RMF Monitor I zz session terminates
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Specify Monitor I data gatherer option NOCRYPTO
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: RMF Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 in ERBMFICA at level UJ04163   *
    ****************************************************************
    * RECOMMENDATION: None, please install this apar.              *
    ****************************************************************
    
    The ABEND0C4 in ERMMFICA occurs trying to access an entry past
    the end of the DACC control block.
    The problem occurs since module ERBMFICA acccess the
    DACC_DOMAIN_ID field in the ICSF DACC control block with an
    incorrect offset.
    
    Affected RMF releases: z/OS-2.3 and z/OS-2.4
    

Problem conclusion

  • Offset to access the DACC_DOMAIN_ID field in ICSF DACC
    control block is now calculated instead of using the offset
    from the ICSF DACC macro.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA60494

  • Reported component name

    RMF DATA GATHER

  • Reported component ID

    566527401

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-16

  • Closed date

    2021-02-11

  • Last modified date

    2021-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ04843 UJ04844

Modules/Macros

  • ERB3GCRY ERBMFDCY ERBMFICA ERBMFICY ERBPPCON ERBSMF70
    

Fix information

  • Fixed component name

    RMF DATA GATHER

  • Fixed component ID

    566527401

Applicable component levels

  • R7B0 PSY UJ04844

       UP21/02/27 P F102 {

  • R7C0 PSY UJ04843

       UP21/02/27 P F102 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7C0"}]

Document Information

Modified date: