A fix is available
APAR status
Closed as new function.
Error description
new function
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: RMF users * **************************************************************** * PROBLEM DESCRIPTION: Enhanced RMF data gathering for ICSF * * operations. * **************************************************************** With this APAR, RMF's Monitor I Crypto data collection is extended to recognize ICSF performance measurements when available: FFX Encipher callable services FFX Decipher callable services FFX Translate callable services QSA Digital Signature Generate callable servies QSA Digital Signature Verify callable servies These measurements are stored in a existing ICSF Data Section of SMF record 70 subtype 2. When this APAR is installed, SMF type 70 subtype 2 record data with SMF record level x'8F' are produced. All other SMF types/subtypes are written with SMF record level '8E'x. Use RMF installations with the PTFs for OA59330 applied to generate RMF Postprocessor Cryptographic Activity reports if the SMF record data were collected on a lower or on the same RMF release level. In this case, the RMF Postprocessor can process the SMF records with SMF record level '8F'x, but does not exploit the new measurements. >>>>> SMF RECORD TYPE 70.2 - RMF PRODUCT SECTION <<<<< The SMF record level change number SMF70SRL at offset 51 (x33) changes to 143 (x8F). >>>>> SMF RECORD TYPE 70 SUBTYPE 2 - CRYPTO ACTIVITY <<<<< OFFSET NAME LEN FORMAT DESCRIPTION FFX and QSA measurements. Fields are only valid if R702CDLV is greater than 22 (x16). 500 x1FA R702FXEC 8 floating Number of calls to encipher data using FFX. 508 x1FC R702FXEB 8 floating Number of bytes of data enciphered using FFX. 516 x204 R702FXEI 8 floating Number of instructions used to encipher data using FFX. 524 x20C R702FXDC 8 floating Number of calls to decipher data using FFX. 532 x214 R702FXDB 8 floating Number of bytes of data deciphered using FFX. 540 x21C R702FXDI 8 floating Number of instructions used to decipher data using FFX. 548 x224 R702FXTC 8 floating Number of calls to translate data using FFX. 556 x22C R702FXTB 8 floating Number of bytes of data translated using FFX. 564 x234 R702FXTI 8 floating Number of instructions used to translate data using FFX. 572 x23C R702DQGC 8 floating Number of calls to generate the QSA digital signatures. 580 x244 16 Reserved 596 x254 R702DQVC 8 floating Number of calls to verify the QSA digital signatures. 604 x25C 16 Reserved KEYWORDS: SMFREC/K
Problem conclusion
Temporary fix
Comments
×**** PE20/11/16 FIX IN ERROR. SEE APAR OA60494 FOR DESCRIPTION
APAR Information
APAR number
OA59330
Reported component name
RMF DATA GATHER
Reported component ID
566527401
Reported release
7C0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2020-03-26
Closed date
2020-10-12
Last modified date
2021-02-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ04163 UJ04165
Modules/Macros
ERB3GCRY ERBMFDCY ERBMFICA ERBMFICY ERBPPCON ERBSMF70
SA380667XX |
Fix information
Fixed component name
RMF DATA GATHER
Fixed component ID
566527401
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7C0"}]
Document Information
Modified date: