OA38218: NEW FUNCTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IOCP users requiring support for the         *
    *                 D/T2827 IBM zEnterprise EC12.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: IOCP New Function                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This PTF introduces a new release of ICP IOCP and is
    VERSION 3 RELEASE 3 LEVEL 0 (3.3.0) of the program.
    ICP IOCP supports the 2827 zEnterprise EC12.
    
    PROBLEM CONCLUSION:
    *
    ICP IOCP VERSION 3 RELEASE 3 LEVEL 0 (3.3.0) provides the
    following support:
      - The 2827 Models (H20, H43, H66, H89, HA1) are supported with
        SYSTEM=(2827,1).  IOCP ignores the MAXDEV keyword on the
        RESOURCE statement and reserves the maximum number of
        devices for this model.  Also, IOCP reserves the maximum
        number of channel subsystems (CSSs) and logical partitions
        for these models.
      - IOCP continues to use a variable amount of storage based
        on the type of IOCDS it is processing.  IOCP requires 130M
        for the 2827 CPC.
      - For 2827 model:
        + ESCON channels CHPID (TYPE=CBY, CVC, CTC, CNC)
          are no longer supported.
    *
    *
    Documentation Changes:
    There is a new publication "Input/Output Configuration
    Program User's Guide for ICP IOCP" which has order number
    SB10-7037-10.  The publication is available using Resource
    Link at http://www.ibm.com/servers/resourcelink by selecting
    section:
    Library > zEnterprise System, EC12
    *
    EC (Engineering Change) Information:
    This PTF level of ICP IOCP contains support for IBM
    zEnterprise EC12 central processor complexes (CPCs).
    See Usage Notes for further information.
    *
    Information on equivalent STAND-ALONE IOCP, z/OS IOCP, z/VM
    IOCP, and z/VSE IOCP follows:
    *
    *
      - Equivalent STAND-ALONE IOCP for ICP IOCP version 3.3.0 is
        in the listed EC's.  The EC's listed are the first levels
        shipped with this release of IOCP.
            EC       MACHINE TYPE
          H09173         2827
    *
      - Equivalent z/OS, z/VM, and VSE IOCP is shipped via the
        listed APARs.
          OPERATING SYSTEM       APAR
               z/OS            OA38218
               z/VM            VM65131
               z/VSE           DY47404, DY47406
    *
    *
    The EC level of the CPC can be determined from the Hardware
    Management Console or Support Element by doing the following:
      1. Open 'Task List' from the 'Views' area.
      2. Open 'Change Management' from the 'Task List Work Area'.
      3. Open 'Groups' from the 'Views' area.
      4. Open the group that contains the CPC you are interested
         in.
      5. Select the CPC.
      6. Open 'System Information' in the 'Change Management'
         tasks area.
    *
    The STAND-ALONE IOCP version and release can be determined by
    looking at the header lines of the IOCP reports produced by
    STAND-ALONE IOCP.  The STAND-ALONE IOCP version and release
    can also be determined from the Hardware Management Console
    or Support Element by doing the following (begin with step 7
    for the Support Element console):
      1. Open 'Task List' from the 'Views' area.
      2. Open 'Recovery' from the 'Task List Work Area'.
      3. Open 'Groups' from the 'Views' area.
      4. Open the group that contains the CPC you are interested
         in.
      5. Select the CPC.
      6. Open 'Single Object Operations' in the 'Recovery'
         tasks area.
      7. Open 'Task List' from the 'Views' area.
      8. Open 'CPC Configuration' from the 'Task List Work Area'.
      9. Open 'Groups' from the 'Views' area.
      10. Open 'Images' from the 'Groups Work Area'.
      11. Select the image to run STAND-ALONE IOCP.
      12. Open 'Input/output (I/O) configuration' in the 'CPC
          Configuration' tasks area.
      13. Select 'View' pull-down.
      14. Select 'Configuration program level'.
    *
    Usage Notes:
    1. If you are currently using a release of ICP IOCP and you do
       not plan on upgrading to one of the listed EC's, you can
       still install this PTF and replace your existing ICP IOCP.
       The 2827 model must power-on reset with an IOCDS written by
       the ICP IOCP shipped by this PTF.  The 2084, 2086, 2094,
       2096, 2097, 2098, 2817 and 2818 models can power-on reset
       with an IOCDS written by the ICP IOCP shipped by this PTF.
       Also, the 2084, 2086, 2094, 2096, 2097, 2098, 2817 and
       2818 models can still power-on reset with an IOCDS that
       was written by your previous release of ICP IOCP.  There is
       no requirement that you write an IOCDS with the ICP IOCP
       shipped by this PTF and perform a power-on reset after the
       PTF has been installed.
    2. Any IOCDS previously created by an ICP version of IOCP
       (z/OS, VM, VSE, or STAND-ALONE) can be reported on by the
       ICP version of IOCP shipped by this PTF.
    3. Any IOCDS previously created by another version of IOCP
       (e.g. IYP IOCP) cannot be reported on by the ICP version of
       IOCP shipped by this PTF or by the STAND-ALONE equivalent
       version of the ICP IOCP program.  (For HCD users, HCD manages
       the correlation of IOCP versions to CPC model for you.)
    4. If you are upgrading to a 2827 model, you must power-on
       reset with an IOCDS written for the 2827.  Following an
       upgrade, you cannot power-on reset with an IOCDS that was
       written for the prior CPC unless the 2827 IOCDS was written
       in preparation of an upgrade.
    5. If you are upgrading to a 2827 model, IBM recommends writing
       an IOCDS to your current 2097 or 2817 CPC as described here.
       Use IOCP execution paramenter CHECKCPC=NO or HCD option
       'Write IOCDS in preparation of upgrade'.  The IOCDS will be
       unusable until your CPC has been upgraded to a 2827.  Inform
       the installing service representative that you have
       pre-written a 2827 IOCDS and which IOCDS should be selected
       after the upgrade.
    6. Although FMID HIO1104 also includes support for
       IXPIOCP (3090, 9021, 9121, and 9221 only), IZPIOCP (2003,
       3000, 7060, 9021, 9121, 9672, and 9674 only), and IYPIOCP
       (2064 and 2066), these programs are not affected by this
       PTF.  Program IOPIOCP (3090 only) will be reused at some
       point in the future for a new processor.
    

Problem conclusion

Temporary fix

Comments

  • ×**** PE12/09/27 FIX IN ERROR. SEE APAR OA40486  FOR DESCRIPTION
    

APAR Information

  • APAR number

    OA38218

  • Reported component name

    IOCP COMMON

  • Reported component ID

    566529101

  • Reported release

    104

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2011-11-30

  • Closed date

    2012-08-27

  • Last modified date

    2013-07-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA90634

Modules/Macros

  • ICPCARDS ICPCARDY ICPCFRST ICPCIOCP ICPPCNTL
    

Publications Referenced
SB10703710    

Fix information

  • Fixed component name

    IOCP COMMON

  • Fixed component ID

    566529101

Applicable component levels

  • R104 PSY UA90634

       UP12/09/05 P F209

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"104","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"104","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 July 2013