Error description

  • Under some heavy loads, status is not returned by the
    Oracle
    Listener in time for the application monitor to consider
    it
    alive, and is reported as having failed.  Unnecessary and
    disruptive recovery is then started.
    

Local fix

Problem summary

  • Under heavy loads, the hard coded 15 second timeout for the
    application monitor may not be sufficient.  Also, under
    such loads, the temporary file used to collect Listener
    status may get reused before it has been processed.
    

Problem conclusion

  • Allow adjustment of timeout.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV77844

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-10-07

  • Closed date

    2016-05-19

  • Last modified date

    2016-05-19

  • APAR is sysrouted FROM one or more of the following:

    IV77161

  • APAR is sysrouted TO one or more of the following:

    IV84993

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

  • R712 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"712","Edition":"","Line of Business":{"code":"","label":""}}]