The example that follows defines two multipath
channel connections for host A500N.
* =====> BEGINNING OF DATA SET MPCCTC50
*************************************************
* CHANNEL-ATTACHMENT MAJOR NODE FOR MPC *
*************************************************
MPCCTC VBUILD TYPE=CA, ** CHANNEL ATTACHMENT MAJOR NODE ** X
CONFGDS=CTC1CKP ** CONFIGURATION RESTART DATASET **
MPCG1 GROUP LNCTL=MPC, ** MULTIPATH CHANNEL CONNECTION ** X
MAXBFRU=16, ** READ SUBCHANNEL BUFFER SIZE ** X
ISTATUS=ACTIVE, ** BECOMES ACTIVE WITH MAJOR NODE** X
REPLYTO=3.0 ** TIMEOUT VALUE FOR MPC XID I/O **
MPCCTC1 LINE READ=(BC2), ** SUBCHANNEL ADDRESS FOR READ ** X
WRITE=(BC1) ** SUBCHANNEL ADDRESS FOR WRITE **
MPCPU1 PU PUTYPE=4,TGN=1 ** LINK STATION FOR ADJACENT HOST**
*
MPCG2 GROUP LNCTL=MPC, ** MULTIPATH CHANNEL CONNECTION ** X
MAXBFRU=16, ** READ SUBCHANNEL BUFFER SIZE ** X
ISTATUS=ACTIVE, ** BECOMES ACTIVE WITH MAJOR NODE** X
REPLYTO=3.0 ** TIMEOUT VALUE FOR MPC XID I/O **
MPCCTC2 LINE READ=(BC5), ** SUBCHANNEL ADDRESS FOR READ ** X
WRITE=(BC4) ** SUBCHANNEL ADDRESS FOR WRITE **
MPCPU2 PU PUTYPE=4,TGN=2 ** LINK STATION FOR ADJACENT HOST**
*
* =====> END OF DATA SET MPCCTC50