Explanation
A DISPLAY EEDIAG,TEST=YES command was issued to
perform an Enterprise Extender connectivity test. VTAM® detected that no EE lines associated with
the local static VIPA address have been activated. At least one EE
line associated with the local static VIPA address you are testing
must be active and available for use.
System action
The DISPLAY EEDIAG,TEST=YES command is not performed.
Operator response
To use the EE connectivity test, perform
the following actions to activate an Enterprise Extender line:
- If a group in the EE XCA major node associated with the local
static VIPA address is defined but is not active, issue a V NET,ACT,ID=groupname,SCOPE=ALL
command to activate these lines.
- If a group was successfully activated, issue the DISPLAY EEDIAG,TEST=YES
command again.
- If a group in the EE XCA major node is not defined, contact the
system programmer.
System programmer response
If no group exists in the EE XCA
major node that is associated with the local static VIPA address,
update the EE XCA major node to define such a group. Then the operator
can issue one the following commands to activate the new definitions:
- To dynamically update the EE XCA major node group, issue the
V NET,ACT,ID=eexcamajornode,UPDATE=ALL
command. See z/OS Communications Server: SNA Operation for more information about using the VARY
command.
- This method for activating the new group might be disruptive if
existing EE connections are active. Issue a V NET,INACT,ID=eexcamajornode,F
command to deactivate Enterprise Extender. Issue a V NET,ACT,ID=eexcamajornode,SCOPE=ALL
command to activate your modified Enterprise Extender definitions.
User response
Problem determination
Source
z/OS® Communications
Server SNA
Module
Routing code
Descriptor code