A command for nodename failed because VTAM® could not obtain a work area to process the request.
VTAM rejects the command.
Messages IST561I, IST562I, IST563I, IST564I, IST565I or IST566I might be issued prior to this message to indicate the type of storage affected.
Issue the DISPLAY BFRUSE command to display storage used by VTAM buffer pools and information about the common service area (CSA). Total VTAM private storage information is also displayed in message IST981I. Issue the DISPLAY STORUSE command to display storage usage for storage pools.
Save the system log and request a dump for problem determination.
If nodename is an independent logical unit that is being converted to a definition for a resource in another domain, then the NCP major node for nodename must be deactivated. Activate the NCP major node when the storage shortage no longer exists.
Verify that the operator entered the buffer pool or CSA start options as specified in the start procedures.
2
5