This trace record is written when an element is dequeued
from a PAB and processing begins on the element.
- Byte (hex)
- Contents
- 00–03
- Record ID: C"REMQ"
- 04
- ID is the primary address space ID (ASID). This field is 0 if
the ASID is greater than X'FF'.
- 05
- 0
- 06
- REMQ instance within issuing module
- 07–0B
- Issuing module name
- 0C
- Conversation FSM state or 0
- 0D
- Router FSM state or 0
- 0E
- Error or failure FSM state or 0
- 0F
- Control block ID
- 10–13
- Information field or 0
- AMU ID if work element is an AMU
- CONTROL and QUALIFY values if work element is an LU6.2 RPL
- Control point operation code if work element is an RUPE
- 0 if work element is a UECB or TQE
- 14–17
- Work element address
- 18–1B
- Address of the PAB from which the work element is being dequeued
- 1C–1F
- Request parameter header (RPH) address