QUEN entry for work element queued to any control block

Entry:
QUEN
VIT option:
PSS
Event:
Work element queued to any control block
VIT processing module:
ISTRACPS
Control is returned to:
ISTAPCTQ
This trace record shows a work element queued to any control block (not just a PAB) to allow another VTAM® routine to further process the work element.
REQTEXT
Byte (hex)
Contents
00–03
Record ID: C"QUEN"
04
ID is the primary address space ID (ASID). This field is 0 if the ASID is greater than X'FF'.
05
Control block ID of work element (See z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures.)
06–07
0
08–0B
Address of PST or 0
0C–0F
Address of the control block field to which the work element is queued
10–13
Address of the issuer of the TPQUE NONE macro
14–17
Address of work element to be queued
18–1B
0
1C–1F
Request parameter header (RPH) address or 0