This trace record is written when an APPC module issues
a macroinstruction to set an RPL6RC nonzero return code. The condition
that this entry records is an exception and is recorded regardless
of whether the APPC VIT option is active.
- Byte (hex)
- Contents
- 00–03
- Record ID: C"ACRC"
- 04
- ID is the primary address space ID (ASID). This field is 0 if
the ASID is greater than X'FF'.
- 05–06
- 0
- 07
- Instance identifier in invoking module
- 08–0B
- Conversation ID
- 0C–0F
- Half-session ID
- 10–13
- Invoking module name
- 14–17
- Address of control block containing return code
- 18–1B
- Return code (RPL6RC)
- 18–19
- Primary return code (RPL6RCPR)
- 1A–1B
- Secondary return code (RPL6RCSC)
- 1C–1F
- Request parameter header (RPH) address