Message IST530I or IST1278I received with NMVT PENDING

z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures
GC27-3667-00

Problem statement
Message IST530I or IST1278I is issued for a PU even though the NetView® program (if installed) or the System p® network management program for System p devices receives session awareness (SAW) data for an SNA device.
Common symptoms
Message IST530I or IST1278I is issued each time the IOPD timer expires. For additional information, see the message descriptions in z/OS Communications Server: SNA Messages.
Probable cause
The device is not real-time monitor capable. This means that the device did not process the response and return the requested information properly to the NetView program for most devices, or to Network Management/6000 for System p devices. A microcode change is needed to permanently resolve this problem.
User response
You can prevent this problem by pointing the device to a KCLASS and using a SAW data filter to stop VTAM® from attempting to collect the data.