Figure 1 depicts a PLU-initiated
session in a SHR-SHR gateway configuration. All SME invocations are
depicted. The alias selection invocations are described in the details
below the figure. Figure 1. PLU-initiated
flows for SHR-SHR
- 2
- VTAM® passes the DLU alias
name, the OLU real name, the associated LU real names, and the logon
mode name as known in the OLU's network. The alias selection function
has the option of returning the DLU real name, the network ID of the
DLU real name, the owning SSCP of the DLU, the OLU and associated
LU alias names as known in the DLU network, and the logon mode name
as known in the DLU network.
- 6
- Same description as number 2.
- 10
- VTAM requests translations
from NETA to NETB for the OLU alias name, the associated LU alias
names, the logon mode name, the COS name, and to translate the COS
name from NETB to NETA.
- 13
- VTAM drives the exit routine
to translate the COS name from NETB to NETA. No attempt is made to
translate the associated LU names because this host has already attempted
to translate them.
|