ACF/TAP treats frame-relay switching equipment (FRSE)
data as non-SNA; therefore, FRSE data does not appear on the report
shown in Figure 1.
Figure 1. Frame-relay data, SNA detail sample report VTAM ADVANCED COMMUNICATIONS FUNCTION
TRACE ANALYSIS PROGRAM
DATE: mm:dd:yyyy SYSTEMS NETWORK ARCHITECTURE DETAIL (SDPRT) PAGE: 00001
2 3 4 5
RECORD/ GROUP ENTRY
MESSAGE SUMMARY D E S C R I P T I V E A N A L Y S I S SUMMARY
0000013
0000010 DATA FLOW 40 00 11 11 20 00 00 0C 00 00 00 03 00 00 00 14 1C 00 00 00 00 00 00 04 00 0B 8B 80 00 01 02 0A 00
03 0F 01 D0
TIMESTAMP: 13.59.53.337525
TH 00-02 FORMAT ID (FID): 4 * TG SWEP:OFF MIG:OFF PCI:OFF * NET PRI:OFF IERN: 01 ERN: 01 *
TH 03-04 VR NUMBER (VRN): 1 * VRCWI: INC TG REORDR REQD: 0 * TP PRI: 1 TG SEQUENCE NUMBER: 000 *
TH 04-06 VRCWRI: R VRRWI: 0 * SINGLY SEQUENCED DATA * VR SEQUENCE NUMBER: 00C *
TH 06- VR PACING: NONE * ORIGIN: 00000014 0000 * SNF SEQUENCE NUMBER: 0004 *
TH -25 SEGMENT(MPF):ONLY * DESTINATION: 00000003 0000 * FLOW: NORMAL COUNT (DCF): 00011 *
RH 00-02 RU TYPE: FM DATA FLOW +RESPONSE* RESPONSE/REQUEST: DR1 * CHAIN: ONLY ELEMENT *
RU FORMAT: FORMATTED * PACING INDICATOR: OFF * *
RU 00- SSCP SERVICES: 02 - CONFIGURATION COMMAND: 0A - ACTIVATE LINK ACTLINK
0000010 USER DATA *..... *
0000029
0000025 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000027 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000030
0000029 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000031
0000031 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000033 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000032
0000035 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000037 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID
0000034
0000039 DATA FLOW 00 10 BF 24 2C FF F0 00 00 00 00 40 08 00 08 3A 02 00 00 00 15 00 00 D2 E3 F3 E2 C1 F2 F1 40 81 00
01 30 04 26 00 B8 00 00 07 00 00 00 00 00
SDLC CMND SDLC UNNUMBERED COMMAND XID - EXCHANGE IDENTIFICATION POLL/FINAL = ON XID