1 |
The page heading contains the report name, report
parameter, and the date on which the report was printed or displayed. |
2 |
- RECORD/TYPE
- The record is the sequence number that ACF/TAP assigns of the
physical line trace record that ACF/TAP was processing when this line
was printed. Entries following the sequence number show the type of
data being traced, which includes the following:
- Internal data
- Controller bus adapter:
- CBS-CHK
- Checkpoint
- CBA-PROC
- Processor
Communication line adapter:
- CLA-CHK
- Checkpoint
- CLA-LSA
- LSA primitives
ESCON® adapter:
- ESCA-CBC
- With controller bus coupler
- ESCA-CBP
- With controller bus processor
- ESCA-DATA
- Data messages
- ESCA-DPSA
- DPSA messages
- ESCA-PCHK
- Processor checkpoint
- ESCA-CCHK
- Coupler checkpoint
Frame-Relay, ISDN, and X.25:
- CSS-CBC
- Controller bus coupler
- CSS-CBP
- Controller bus processor
- CSS-CDIM
- CDIM messages
- CSS-CHK
- Checkpoint
- CSS-CSS
- Connectivity subsystem
- CSS-LSA
- LSA primitives
|
2 (Continued) |
- CSS-MSG
- Messages
- CSS-SSA
- SSA primitives
- ISDN-CHK
- Checkpoint (ISDN only)
Mapper:
- MAPR-CBC
- With controller bus coupler
- MAPR-CBP
- With controller bus processor
- MAPR-CDIM
- CDIM messages
- MAPR-LSA
- LSA primitives
- MAPR-MSG
- Messages
- MAPR-SSA
- SSA primitives
|
2 (Continued) |
Token ring adapter
- TRA-PSSA
- SSA primitives
- TRA-LSA
- LSA primitives
- TRA-CDIM
- CDIM messages
- External data
- Controller bus adapter:
- CBA-CPLR
- Coupler
Communication line adapter:
- CLA-PIU
- Path information unit
- CLA-MAC
- MAC MODEM
ESCON adapter:
- ESCA-PIU
- Path information unit
- ECSA-CPLR
- Coupler
Frame relay:
- FRLY-FRFH
- Frame-relay frame handler
- FRLY-FRTE
- Frame-relay terminal equipment
- FRLY-HPR
- High performance routing
- FRLY-IP
- Internet Protocol
- FRLY-LMI
- Local management interface
Internet Protocol:
- IP-RECV
- Receive data
- IP-XMIT
- Transmit data
|
2 (Continued) |
ISDN:
- ISDN-LIC
- Line interface data
- ISDN-RECV
- Receive data
- ISDN-XMIT
- Transmit data
Token ring adapter:
- TRA-CPLR
- Coupler
X.25 adapter:
- X.25–RECV
- Receive
- X.25–XMIT
- Transmit
|
3 |
- ELEM ADDRESS
- The element address of the physical line that was being traced.
|
4 |
- HOST LINK
- The logical line number of the line that was being traced.
|
5 |
- HOST STATION
- The logical station number of the station that was being traced.
|
6 |
- ADAPTER-ID
- The logical adapter number given by the NCP in the TRACE START
NDPSA.
|
7 |
- LINE-ADDRESS
- The relative line number in the processor of the line that was
being traced.
|
8 |
- CBA-ID
- The logical adapter number of the controller bus adapter.
|
9 |
- COMMAND QUALIFIER
- The command and qualifier that was being processed when the trace
record was written.
|
10 |
- TIME
- The time that elapsed (in hexadecimal format) between the entries,
to the nearest 100 milliseconds. The time is measured from the activation
of the trace to the second-level interrupt represented by each entry.
|
11 |
- SEQ
- The sequence counter from the CSS control block that is being
displayed.
|
12 |
- HEX
- The hexadecimal trace entry from the control block.
|
13 |
- TRANSLATION
- The EBCDIC equivalent of the hexadecimal trace data.
|
14 |
Pertinent fields are extracted from the preceding
trace entry and are displayed on a separate line as field names, followed
by their corresponding values in parentheses. |
15 CSS token-ring data reports only |
The command identifier for transmit or receive
token-ring frames. The following are examples: XMT RR .C,F, NR=74
RCV RR .R,F, NR=48
where: - XMT
- Transmit frame
- RCV
- Receive frame
- Information frame
- I
- Supervisory frame
- RR, RNR, REJ
- Unnumbered frame
- DM, DISC, FRMR, SABME, SIM, TEST, UA, XID
- C
- Command
- R
- Response
- P
- Poll
- F
- Final
- NR
- Number of information and supervisory frames received
- NS
- Number of information and supervisory frames sent
- Blank
- Unnumbered frame
|