z/OS Communications Server: ACF/TAP Trace Analysis Handbook
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


LONGPIU parameter

z/OS Communications Server: ACF/TAP Trace Analysis Handbook
GC27-3645-00

This parameter controls the number of bytes that ACF/TAP uses to format line trace data or VTAM® full buffer trace data.

Read syntax diagramSkip visual syntax diagram
   .-LONGPIU=NO--.   
>>-+-------------+---------------------------------------------><
   '-LONGPIU=YES-'   

NO
This is the default if a value is not specified or the parameter is reset. The length of the trace data is set to a maximum of 252 bytes.
YES
If you specify this value when formatting normal-mode line trace data, ACF/TAP can format up to 4092 bytes of data on the following reports:
  • Line trace detail
  • SNA detail
  • Network data traffic
  • Frame-relay logical line trace summary
  • SYSPRINT

If you specify this value when formatting VTAM full buffer trace data, ACF/TAP can format up to 4096 bytes of data on the SNA detail, network data traffic, and SYSPRINT reports.

Go to the previous page Go to the next page