IGD318I DATA SET ALLOCATION REQUEST FAILED - NO POOL OR VIO STORAGE
GROUPS SELECTED FOR DATA SET dsn1 WHICH REFERENCES
DATA SET dsn2 ExplanationAn allocation for a new data set specified a VOL=REF that referenced the specified SMS-managed data set. Because VOL=REF was specified, the two data sets must reside in compatible types of storage groups. The storage group ACS routine did not assign a storage group of the specified type to the referencing data set. In
the message text:
System actionAllocation of the data set fails. User responseDo one of the following:
Storage Administrator Response: If the VOL=REF specification is used correctly, modify the storage group ACS routine so that it assigns storage groups of the appropriate type or types to the referencing data set. SourceStorage management subsystem (SMS) ModuleIGDIDMCD, IGDVRFSG Routing code2,Note 28 Descriptor code4 |