IGD051I FAILED INSTALLATION EXIT exitname IS NOW
DEACTIVATED ExplanationThe installation exit failed; and during ACS processing, the storage management subsystem will not re-invoke the exit until the SMS address space is restarted. The SMS address space may be restarted by a re-IPL of the system, or by a restart of the storage management subsystem after six failures. This message is accompanied by IGD307I, which further indicates the reason for the deactivation. In
the message text:
System actionThe system bypasses further processing of this exit. Operator responseTell the system programmer about this message. System programmer responseMake sure exitname does not set a return code of anything other than 0, 4 or 16; if exitname returns an unexpected code, the exit is deactivated. If the return code is note the cause of the problem, use message IGD307I, the logrec data set, and SYS1.DUMPnn to determine why the exit failed. SourceDFSMSdfp Routing code2,10 Descriptor code4 |